title: "GFC Mass Flow Controller, Aluminum or Steel — Analyt-MTC"
url: https://analyt-mtc.com/catalog/product/gfc/
lang: en
alternates:
  de: https://analyt-mtc.com/de/catalog/product/gfc-2/
  en: https://analyt-mtc.com/catalog/product/gfc/
  fr: https://analyt-mtc.com/fr/catalog/product/gfc-3/
---

![GFC, 3D view](https://analyt-mtc.com/media/GFC17S-VAL6-A0_3D.png)

1 / 2

ANALYT-MTC

# GFC

GFC mass flow controller: low priced aluminum or stainless steel thermal mass flow controllers with integrated solenoid valve, tiltable LCD and flow ranges up to 1000 sL/min N2.

Documents

[GFC Mass Flow Controllers — Technical data sheet · Rev. 2](https://analyt-mtc.com/documents/gfc-spec-sheet-en.pdf) ([text version](https://analyt-mtc.com/documents/gfc-spec-sheet-en.md)) [GFC Mass Flow Controller — Operating manual · Rev. 2](https://analyt-mtc.com/documents/gfc-manual-en.pdf) ([text version](https://analyt-mtc.com/documents/gfc-manual-en.md))

GFC mass flow controllers are compact controllers designed to measure and regulate flow rates of gases. Using thermal mass flow metering and electomagnetic valve, they offer accuracy and high cost efficiency. They belong to the [thermal mass flow controllers](https://analyt-mtc.com/catalog/thermal-mass-flow-controllers/) range and can be configured for flow ranges from 10 smL/min to 1000 sL/min N2. The [DFC](https://analyt-mtc.com/catalog/product/dfc/) is the digital alternative in the same range.

## Which GFC for corrosive gases: aluminum or stainless steel?

Each controller is equipped with an advanced “U”-shape tube sensor in conjunction with flow passage elements constructed of aluminum and brass for non-corrosive gases or 316 stainless steel for corrosive applications.

## What accuracy and response time do GFC models have?

-   GFC 17, 37, 47: +/- 1.0% full scale.
-   GFC 57, 67, 77: +/- 1.5% full scale from 20% to 100%, and +/- 3% full scale from 0% to 20%.
-   Repeatability: +/- 0.5% of full scale.
-   Response to within +/-2% of set flow rate, over 25% to 100% full scale flow: 1 second on the GFC 17, 2 seconds on the GFC 37/47 and 5 seconds on the GFC 57/67/77.

## How do I read, connect and upgrade a GFC?

The LCD readout built into the top of the transducer is tiltable over 90 degrees to provide optimal reading comfort. It is connected to the transducer by a standard modular plug, and is readily removable for remote reading installations. Transducers without LCD readout are offered for OEM applications.

The controller can be connected to the process with 1/4”, 3/8”, 1/2” compression fittings and 3/4” FNPT fittings. Optional fittings are available. They can be used as benchtop units or mounted with screws in the base.

GFC can be upgraded with a [TIO](https://analyt-mtc.com/catalog/product/tio-accessory-totalizer-input-output/) to add digital communication, Programmable set point, Up to 47 different volumetric and mass flow engineering units and Totalizer.

| Parameter | Value |
| --- | --- |
| **Accuracy** | GFC 17, 37, 47 : +/- 1.0% full scale. / GFC 57, 67, 77 : +/- 3% full scale, from 0% to 20% / GFC 57, 67, 77 : +/- 1.5% full scale, from 20% to 100% |
| **Calibrations** | Performed at standard conditions (1013 hPa) & (21.11°C). |
| **Repeatability** | +/- 0.5% of full scale. |
| **Response Time** | GFC 17 : 1 second to within +/-2% of set flow rate, over 25% to 100% full scale flow / GFC 37/47 : 2 seconds to within +/-2% of set flow rate, over 25% to 100% full scale flow / GFC 57/67/77 : 5 seconds to within +/-2% of set flow rate, over 25% to 100% full scale flow |
| **Gas Temp. & ambient Temp.** | Gas temp (0°C to 50°C). / Ambient temp (-10°C to 50°C). |
| **Output signals** | Linear 0-5 Vdc, and 4-20mA 0-500 Ohms loop resistance. / Max noise +/-20mV |
| **Gas pressure** | GFC 17, 37, 47 : Max. 70 barg. Optimal pressure 1.7 barg. / GFC 57, 67, 77 : Max 34.5 barg. Optimal pressure 1.7 barg. |
| **Materials** | Anodized aluminum, brass and Viton O-rings for Aluminum models. / 316 stainless steel and Viton O-rings (Optional Bruna, EPR or Kalrez) for stainless steel models. |
| **Connections** | GFC 17: 1/4″ compression fittings, Optional: 6mm, 3/8″ and 1/8″ compression fittings or 1/4″ VCR®. / GFC 37: 1/4″ compression fittings, Optional: 6mm and 3/8″ compression fittings or 1/4″ VCR®. / GFC 47: 3/8″ compression fittings. / GFC 57: 3/8″ compression fittings. / GFC 67: 1/2″ compression fittings. / GFC 77: 3/4″ compression fittings or FNTP fittings |

| Description | Part Number |  |  |
| --- | --- | --- | --- |
| Remote LCD readout with 3 feet long cable | **17/R** |   ![GFC](https://analyt-mtc.com/illustrations/accessories/acc-remote-lcd-readout.webp) |  |
| Power Supply, 230 V/12 Vdc EU (no support for analog interface) | **PSGFC-12V** |  |  |
| Power Supply, 230 V/24 Vdc EU (no support for analog interface) | **PSGFC-24V** |  |  |
| Universal Baseplate : / A universal bench top stand commonly used with our flowmeters, controllers or rotameters. | **35780** |   ![GFC](https://analyt-mtc.com/illustrations/accessories/acc-35780.webp) |  |
| Pelicase for maximum safety during transport | **1200-000-110E** |   ![GFC](https://analyt-mtc.com/illustrations/accessories/acc-pc-1400-001-110e-1.webp) |  |

## Questions about this product?

Our application engineers aim to reply within 3 business hours.