title: "Gastec Injection Type Tubes: CO2 and Propane — Analyt-MTC"
url: https://analyt-mtc.com/catalog/product/gastec-injection-type-tubes/
lang: en
alternates:
  de: https://analyt-mtc.com/de/catalog/product/gastec-injection-type-tubes-2/
  fr: https://analyt-mtc.com/fr/catalog/product/tubes-de-type-injection-gastec/
  en: https://analyt-mtc.com/catalog/product/gastec-injection-type-tubes/
---

![Gastec Injection Type Tubes](https://analyt-mtc.com/illustrations/gastec-injection-type-tubes.webp)

GASTEC

# Gastec Injection Type Tubes

Gastec injection type tubes use an injector tube to sample gas samples, which is inserted into a detector tube to perform measurements.

Documents

[GASTEC detector tubes — Reference guide · Rev. 2](https://analyt-mtc.com/documents/gastec-detector-tube-reference-en.pdf) ([text version](https://analyt-mtc.com/documents/gastec-detector-tube-reference-en.md))

Gastec injection type tubes are detector tubes for high-concentration carbon dioxide and propane. They use an injector tube to sample gas samples, which is inserted into a detector tube to perform measurements; a syringe injects a fixed sample into the tube. They belong to the [Gastec detector tubes](https://analyt-mtc.com/catalog/gastec-colorimetric-detector-tubes/) range. Tubes are supplied in packs for 10 tests.

## Which gases do injection type tubes measure?

-   Carbon dioxide, tube GST\_2HT: 10 % – 100 %, sampling time in seconds: 20
-   Propane, tube GST\_100B: 0.1 % – 2 %, sampling time in seconds: 120

## How is a sample taken with an injection type tube?

1.  Break off both ends of a detector tube.
2.  Attach the syringe inlet to the syringe.
3.  Collect 20ml of sample into the syringe by pulling its piston.
4.  Insert the tube securely into the detector tube for the specified sampling time.

The Specifications tab lists the tubes with their part numbers.

| Chemical | Tube Name | Measuring Range | Sampling Time (secs) | Part Number |  |
| --- | --- | --- | --- | --- | --- |
| Carbon dioxide / CO2 | Carbon dioxide | 10 % – 100 % | 20 | [GST\_2HT](https://analyt-mtc.com/media/2HT.pdf) |  |
| Propane / CH3CH2CH3 | Propane | 0.1 % – 2 % | 120 | [GST\_100B](https://analyt-mtc.com/media/100B.pdf) |  |

Uses an injector tube to sample gas samples, which is inserted into a detector tube to perform measurements. Detector tubes used for high concentration carbon dioxide and propane gases apply this feed-in method.

![Gastec Injection Type Tubes](https://analyt-mtc.com/media/inj-type-0_Front-300x120.png)

Stage 1 – Break off both ends  
of a detector tube

![Gastec Injection Type Tubes](https://analyt-mtc.com/media/inj-type-1_Front-300x120.png)

Stage 2 – Attach the syringe  
inlet to the syringe

![Gastec Injection Type Tubes](https://analyt-mtc.com/media/inj-type-2_Front-300x120.png)

Stage 3 – Collect 20ml of  
sample into the syringe by  
pulling its piston.

![Gastec Injection Type Tubes](https://analyt-mtc.com/media/inj-type-3_Front-300x120.png)

Stage 4 – Insert tube securely  
into the detector tube for  
specified sampling time

Tubes are supplied in packs for 10 tests.

## Questions about this product?

Our application engineers aim to reply within 3 business hours.

[Ask an engineer](https://analyt-mtc.com/contact/?ask=1&about=Gastec%20Injection%20Type%20Tubes)