# Face Level Sampling

The SKC Mini Sampler fits onto the Face Level Sampling Headset for welding fume sampling inside masks and helmets, and requires a 13 mm 0.8 µm MCE Filter.

Documents

[SKC Face Level Sampling Headset — Technical data sheet · Rev. 2](https://analyt-mtc.com/documents/skc-face-level-headset-spec-sheet-en.pdf) ([text version](https://analyt-mtc.com/documents/skc-face-level-headset-spec-sheet-en.md)) [SKC Face Level Sampling Headset — Instructions for use · Rev. 2](https://analyt-mtc.com/documents/skc-face-level-headset-instructions-en.pdf) ([text version](https://analyt-mtc.com/documents/skc-face-level-headset-instructions-en.md)) [SKC Mini-Sampler for Welding Aerosol — Instructions for use · Rev. 2](https://analyt-mtc.com/documents/skc-mini-sampler-instructions-en.pdf) ([text version](https://analyt-mtc.com/documents/skc-mini-sampler-instructions-en.md))

The SKC Face Level Sampling Headset is a personal air sampling media holder for taking samples inside personal protective equipment (PPE) such as masks and helmets. Two flexible sampling arms take parallel, simultaneous samples of the inhalable fraction, and the headset is particularly suitable for sampling hazardous metals in welding fume (such as manganese, nickel, chrome, etc). It belongs to the [particle size selective sampling](https://analyt-mtc.com/catalog/particle-size-selective-sampling/) range.

## How does welding fume sampling inside a helmet work?

The headset is lightweight and comfortable, and it fits inside welding masks and helmets. Its main points:

-   Dual flexible arms for simultaneous sampling
-   Samples the inhalable fraction
-   Meets BS EN ISO 10882-1:2011 – Health Safety in Welding and Allied Processes: Sampling of Airborne Particles
-   With the appropriate accessories it takes a Mini Sampler for particulates or 6 x 70mm sorbent tubes for vapours

The headset was developed in a research project partly funded by the Swedish Work Environment Authority and carried out at Stockholm University, Sweden.

## Why sample welding fume?

In February 2019 HSE issued a [safety alert on welding fume](https://www.hse.gov.uk/safetybulletins/mild-steel-welding-fume.htm?utm_name=&utm_term): new evidence shows that exposure to mild steel welding fume can cause cancer. Employers should use suitable controls for all welding work; HSE has published Control of Substances Hazardous to Health direct advice for welding and web pages on [how to manage exposure to welding fume](https://www.hse.gov.uk/welding/). HSE (29th June 2021) also states that breathing in welding fume and metalworking fluids can cause serious lung diseases.

## Which sampling package fits ISO 10882-1?

For welding fume particulate metals such as manganese from the breathing zone inside a welder’s face mask, the recommended method and equipment in ISO Standard 10882-1 give this package:

-   Part No: 210-3311 [AirChek 3000 Pump](https://analyt-mtc.com/catalog/product/skc-airchek-3000-pump/)
-   Part No: 223-240A AirChek 3000 Pump Fast Charger
-   Part No: 375-0550 chek-mate Calibrator
-   Part No: 225-6200 Face Level Headset
-   Part No: 225-6201 Mini Sampler and Tubing
-   Part No: 225-6202 Calibration Adaptor for Mini Sampler

To also sample inhalable and respirable dust and airborne metals under the current HSE methods, use the 210-3311KP [AirCheck 3000 Pump Dust Kit](https://analyt-mtc.com/catalog/product/dust-sampling-kits/) in place of the pump and charger, with the same calibrator, headset, Mini Sampler and calibration adaptor (375-0550, 225-6200, 225-6201, 225-6202).

Neither package contains media. The Mini Sampler requires a [13mm MCE 5.0 µm Filter, part number 225-8050](https://analyt-mtc.com/catalog/product/mixed-cellulose-ester-membrane-filters/).

| Description | Part Number |  |
| --- | --- | --- |
| Face Level Sampling Headset, supplied with 2 flexible arms, 4 hose connectors, 2 Luer plugs and 2 Luer connectors | **225-6200** |  |

| Description | Part Number |  |  |
| --- | --- | --- | --- |
| Mini Sampler with Tubing | **225-6201** |   ![Face Level Sampling](https://analyt-mtc.com/illustrations/accessories/acc-225-6201-3d.webp) |  |
| Tube Holder and Cover | **225-6220** |   ![Face Level Sampling](https://analyt-mtc.com/illustrations/accessories/acc-225-6220-3d.webp) |  |
| Calibration Adaptor with Tubing for Mini Sampler | **225-6202** |   ![Face Level Sampling](https://analyt-mtc.com/illustrations/accessories/acc-225-6202-3d.webp) |  |

## Questions about this product?

Our application engineers aim to reply within 3 business hours.

[Ask an engineer](https://analyt-mtc.com/contact/?ask=1&about=Face%20Level%20Sampling)