title: "Passive air samplers and diffusive badges — Analyt-MTC"
url: https://analyt-mtc.com/catalog/passive-samplers/
lang: en
alternates:
  de: https://analyt-mtc.com/de/catalog/passivsammler/
  en: https://analyt-mtc.com/catalog/passive-samplers/
---

# Passive Samplers

Passive air samplers: diffusive badges and tubes that collect gases and vapours without a pump, at a validated uptake rate, then go to the lab for analysis. The range covers broadband organic-vapour badges and compound-specific samplers for formaldehyde, SO2/NO2, ammonia, ethylene oxide, HCN, mercury and ozone — from SKC.

![SKC](https://analyt-mtc.com/_astro/skc.Bk3xP0Oj.svg)![SKC](https://analyt-mtc.com/_astro/skc-white.bbpzr2g0.svg)

## At a glance

-   Uptake rates 15 to 40 mL/min
-   Validated to ASTM D6246, ANSI/ISEA 104
-   UMEx badge 8.6 x 2.8 x 0.89 cm, 11 g
-   Sampling from 15 minutes to 7 days

## All models

10 models

-     ![](https://analyt-mtc.com/illustrations/skc-organic-vapour-passive-samplers.webp)
    
    ### [Organic Vapour Passive Samplers](https://analyt-mtc.com/catalog/product/skc-organic-vapour-passive-samplers/)
    
    Broadband VOC Chek 575 badge with sampling rates for 300+ compounds; choice of charcoal or Anasorb 747.
    
    350 mg charcoal · 300+ VOCs
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-organic-vapour-passive-samplers/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-ultra-passive-samplers.webp)
    
    ### [ULTRA Passive Samplers](https://analyt-mtc.com/catalog/product/skc-ultra-passive-samplers/)
    
    Diffusive sampler for sub-ppb to ppt VOCs and SVOCs; a pump-free thermal-desorption alternative to EPA TO-17.
    
    5 sorbents · sub-ppb to ppt
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-ultra-passive-samplers/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-umex-100-passive-sampler-for-formaldehyde.webp)
    
    ### [UMEX100 Passive Sampler CH2O](https://analyt-mtc.com/catalog/product/skc-umex-100-passive-sampler-for-formaldehyde/)
    
    Single-use badge for formaldehyde and aldehydes using 2,4-DNPH chemistry; meets OSHA 1007 and ISO 16000-4.
    
    28.6 mL/min · LOD 2 ppb
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-umex-100-passive-sampler-for-formaldehyde/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-umex-200-passive-sampler-so2-no2.webp)
    
    ### [UMEx 200 Passive Sampler SO2/NO2](https://analyt-mtc.com/catalog/product/skc-umex-200-passive-sampler-so2-no2/)
    
    Single-use badge for sulphur dioxide and/or nitrogen dioxide; TEA chemistry as in active OSHA ID-182.
    
    SO2 15.2 · NO2 17.3 mL/min
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-umex-200-passive-sampler-so2-no2/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-umex-300-passive-sampler-ammonia.webp)
    
    ### [UMEx 300 Passive Sampler Ammonia](https://analyt-mtc.com/catalog/product/skc-umex-300-passive-sampler-ammonia/)
    
    Single-use ammonia badge with sulphuric-acid tape; chemistry as in OSHA ID-188 and NIOSH 6016, 0.1–100 ppm.
    
    39.92 mL/min · 0.1–100 ppm
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-umex-300-passive-sampler-ammonia/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-ethylene-oxide-passive-samplers.webp)
    
    ### [Ethylene Oxide Passive Samplers](https://analyt-mtc.com/catalog/product/skc-ethylene-oxide-passive-samplers/)
    
    Ethylene oxide badge using the same sorbent as active OSHA 1010; ideal for hospitals and sterile-supply sites.
    
    21.2 mL/min · 0.1–4 ppm
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-ethylene-oxide-passive-samplers/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-hydrogen-cyanide-passive-samplers.webp)
    
    ### [Hydrogen Cyanide Passive Samplers](https://analyt-mtc.com/catalog/product/skc-hydrogen-cyanide-passive-samplers/)
    
    Miniature HCN badge specified in OSHA Method 1015; soda-lime sorbent loads from a vial in the field.
    
    28.4 mL/min · 0.44–20 ppm
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-hydrogen-cyanide-passive-samplers/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-elemental-mercury-passive-sampler.webp)
    
    ### [Elemental Mercury Passive Sampler](https://analyt-mtc.com/catalog/product/skc-elemental-mercury-passive-sampler/)
    
    Reusable-holder badge for elemental mercury vapour (TWA); Anasorb C300 capsule, validated to OSHA ID-140.
    
    Anasorb C300 · up to 120 h
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-elemental-mercury-passive-sampler/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-ozone-test-strips.webp)
    
    ### [Ozone Test Strips](https://analyt-mtc.com/catalog/product/skc-ozone-test-strips/)
    
    Colour-change strips giving a 10-minute visual read of ozone from under 45 to over 105 ppb — no pump or lab.
    
    45–105 ppb · 10-min read
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-ozone-test-strips/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-passive-thermal-desorption-tubes-2.webp)
    
    ### [Passive Thermal Desorption Tubes](https://analyt-mtc.com/catalog/product/skc-passive-thermal-desorption-tubes-2/)
    
    Pump-free diffusive TD tube for outdoor benzene and VOC monitoring; sorbent Carbopack X or Anasorb GCB1.
    
    Carbopack X/GCB1 · EPA 325A
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-passive-thermal-desorption-tubes-2/)
    

## Related families

  ![](https://analyt-mtc.com/illustrations/skc-impingers.webp)

### [Impingers](https://analyt-mtc.com/catalog/impingers/)

1 model

  ![](https://analyt-mtc.com/illustrations/skc-tedlar-sample-bags.webp)

### [Sample Bags](https://analyt-mtc.com/catalog/sample-bags/)

6 models

  ![](https://analyt-mtc.com/illustrations/skc-silica-gel-sorbent-tubes.webp)

### [Sorbent tubes](https://analyt-mtc.com/catalog/sorbent-tubes/)

14 models

## What is a passive air sampler?

A passive air sampler collects gases and vapours by diffusion, with no pump. The badges and tubes sample at a validated uptake rate, 15 to 40 mL/min across the range, for anything from 15 minutes to 7 days, and then go to the lab; the ozone test strips are the exception and are read on site. The organic-vapour badges follow ASTM D6246 and ANSI/ISEA 104, and the ethylene oxide badge ANSI/ISEA 104.

## Broadband or compound-specific diffusive sampler?

For mixed vapours, the [organic vapour passive samplers](https://analyt-mtc.com/catalog/product/skc-organic-vapour-passive-samplers/) are broadband: the VOC Chek 575 badge has sampling rates for 300+ compounds, with charcoal or Anasorb 747. For trace levels, [ULTRA passive samplers](https://analyt-mtc.com/catalog/product/skc-ultra-passive-samplers/) cover sub-ppb to ppt VOCs and SVOCs as a pump-free thermal-desorption alternative to EPA TO-17, and [passive thermal desorption tubes](https://analyt-mtc.com/catalog/product/skc-passive-thermal-desorption-tubes-2/) suit outdoor benzene and VOC monitoring.

## Which diffusion badge for formaldehyde, ammonia or other gases?

[UMEX100](https://analyt-mtc.com/catalog/product/skc-umex-100-passive-sampler-for-formaldehyde/) samples formaldehyde and aldehydes and meets OSHA 1007 and ISO 16000-4. [UMEx 200](https://analyt-mtc.com/catalog/product/skc-umex-200-passive-sampler-so2-no2/) covers SO2 and NO2, and [UMEx 300](https://analyt-mtc.com/catalog/product/skc-umex-300-passive-sampler-ammonia/) covers ammonia at 0.1–100 ppm. The [ethylene oxide](https://analyt-mtc.com/catalog/product/skc-ethylene-oxide-passive-samplers/) badge reads 0.1–4 ppm, and the [hydrogen cyanide](https://analyt-mtc.com/catalog/product/skc-hydrogen-cyanide-passive-samplers/) badge 0.44–20 ppm. The [elemental mercury](https://analyt-mtc.com/catalog/product/skc-elemental-mercury-passive-sampler/) badge samples for up to 120 h. [Ozone test strips](https://analyt-mtc.com/catalog/product/skc-ozone-test-strips/) give a 10-minute visual read from 45–105 ppb, with no pump or lab.

## Questions about these products?

Our application engineers aim to reply within 3 business hours.

[Ask an engineer](https://analyt-mtc.com/contact/?ask=1)