title: "Particulate samplers, filters and cyclones — Analyt-MTC"
url: https://analyt-mtc.com/catalog/particulate-sampling/
lang: en
alternates:
  de: https://analyt-mtc.com/de/catalog/partikel-probenahme-de/
  en: https://analyt-mtc.com/catalog/particulate-sampling/
---

# Particulate Sampling

Particulate samplers collect airborne dust, fibres and particulate onto filters for gravimetric or chemical analysis. The section spans membrane and depth filters, cassette hardware, size-selective cyclones and impactors, and direct-reading dust monitors — from SKC.

![SKC](https://analyt-mtc.com/_astro/skc.Bk3xP0Oj.svg)![SKC](https://analyt-mtc.com/_astro/skc-white.bbpzr2g0.svg)

Choose your technology

  ![](https://analyt-mtc.com/illustrations/sureseal-cassette-blanks.webp)

## [Filter And Cassettes Accessories](https://analyt-mtc.com/catalog/filter-and-cassettes-accessories/)

Cassette hardware — holders, supports, blanks and storage, but no filter media.

7 models

  ![](https://analyt-mtc.com/illustrations/mixed-cellulose-ester-membrane-filters.webp)

## [Filters And Cassettes](https://analyt-mtc.com/catalog/filters-and-cassettes/)

The filter media themselves — choose by material and pore to capture your analyte.

12 models

  ![](https://analyt-mtc.com/illustrations/diesel-particulate-matter-dpm-cyclone.webp)

## [Particle Size-Selective Sampling](https://analyt-mtc.com/catalog/particle-size-selective-sampling/)

Choose when you need a specific size fraction — respirable, thoracic, inhalable or PM.

15 models

  ![](https://analyt-mtc.com/illustrations/haz-dust-iv-particulate-monitor.webp)

## [Particulate Monitors](https://analyt-mtc.com/catalog/particulate-monitors/)

Choose for instant real-time dust readings without a lab weighing step.

7 models

## [Filter And Cassettes Accessories](https://analyt-mtc.com/catalog/filter-and-cassettes-accessories/)

7 models

-     ![](https://analyt-mtc.com/illustrations/sureseal-cassette-blanks.webp)
    
    ### [SureSeal Cassette Blanks](https://analyt-mtc.com/catalog/product/sureseal-cassette-blanks/)
    
    Empty two- and three-piece filter housings — clear styrene, solvent-resistant or conductive; leak-tested.
    
    25, 37, 47 mm · 2 or 3-piece
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/sureseal-cassette-blanks/)
    
-     ![](https://analyt-mtc.com/illustrations/cassette-shrink-bands.webp)
    
    ### [Cassette Shrink Bands](https://analyt-mtc.com/catalog/product/cassette-shrink-bands/)
    
    Self-sealing, tamper-evident bands with a writable surface for sample ID; six colours, 25 and 37 mm.
    
    25 & 37 mm · 6 colours
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/cassette-shrink-bands/)
    
-     ![](https://analyt-mtc.com/illustrations/cassette-and-filter-holders.webp)
    
    ### [Cassette and Filter Holders](https://analyt-mtc.com/catalog/product/cassette-and-filter-holders/)
    
    Reusable in-line and open-face holders from 13 to 47 mm in polypropylene, Delrin, polycarbonate or PFA.
    
    13, 25, 37, 47 mm
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/cassette-and-filter-holders/)
    
-     ![](https://analyt-mtc.com/illustrations/filter-supports.webp)
    
    ### [Filter Supports](https://analyt-mtc.com/catalog/product/filter-supports/)
    
    Backing pads and screens under the filter — cellulose, porous plastic or stainless-steel mesh, 25 to 47 mm.
    
    25, 37 and 47 mm
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/filter-supports/)
    
-     ![](https://analyt-mtc.com/illustrations/cassette-inserts.webp)
    
    ### [Cassette Inserts](https://analyt-mtc.com/catalog/product/cassette-inserts/)
    
    Solu-CAP and Accu-CAP dome capsules that capture the whole sample and end cassette wall losses; 37 mm.
    
    37 mm · 0.8 µm MCE
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/cassette-inserts/)
    
-     ![](https://analyt-mtc.com/illustrations/cassette-and-filter-storage.webp)
    
    ### [Cassette and Filter Storage](https://analyt-mtc.com/catalog/product/cassette-and-filter-storage/)
    
    Cases, petri slides, glass jars and Filter-Keeper clamshells for storing and transporting filters to 47 mm.
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/cassette-and-filter-storage/)
    
-     ![](https://analyt-mtc.com/illustrations/filter-sampling-accessories.webp)
    
    ### [Filter Sampling Accessories](https://analyt-mtc.com/catalog/product/filter-sampling-accessories/)
    
    Handling tools — forceps, SureSeal openers, filter lifters, collar clips, tubing, adaptors and sample labels.
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/filter-sampling-accessories/)
    

## [Filters And Cassettes](https://analyt-mtc.com/catalog/filters-and-cassettes/)

12 models

-     ![](https://analyt-mtc.com/illustrations/mixed-cellulose-ester-membrane-filters.webp)
    
    ### [Mixed Cellulose Ester Membrane Filters](https://analyt-mtc.com/catalog/product/mixed-cellulose-ester-membrane-filters/)
    
    Hydrophilic standard for airborne metals and asbestos fibre counting; dissolves fully for AAS/ICP.
    
    0.45–5.0 µm · 13–47 mm · MCE
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/mixed-cellulose-ester-membrane-filters/)
    
-     ![](https://analyt-mtc.com/illustrations/ptfe-polytetrafluoroethylene-filters.webp)
    
    ### [PTFE (Polytetrafluoroethylene) Filters](https://analyt-mtc.com/catalog/product/ptfe-polytetrafluoroethylene-filters/)
    
    Hydrophobic and solvent-resistant, low tare mass — for size-selective samplers and humid aerosols to 260 °C.
    
    0.3–10 µm · 13–47 mm · PTFE
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/ptfe-polytetrafluoroethylene-filters/)
    
-     ![](https://analyt-mtc.com/illustrations/gla-5000-pvc-membrane-filters.webp)
    
    ### [GLA 5000 PVC Membrane Filters](https://analyt-mtc.com/catalog/product/gla-5000-pvc-membrane-filters/)
    
    Low-tare, hydrophobic media for silica, metals and dust; meets OSHA ID-215 for hexavalent chromium.
    
    5.0 µm · 25–47 mm · PVC
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/gla-5000-pvc-membrane-filters/)
    
-     ![](https://analyt-mtc.com/illustrations/polycarbonate-membrane-filters.webp)
    
    ### [Polycarbonate Membrane Filters](https://analyt-mtc.com/catalog/product/polycarbonate-membrane-filters/)
    
    Smooth-surface film for light and electron microscopy; thin, non-staining, very low tare, to 140 °C.
    
    0.4–0.8 µm · 25–47 mm
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/polycarbonate-membrane-filters/)
    
-     ![](https://analyt-mtc.com/illustrations/silver-membrane-filters.webp)
    
    ### [Silver Membrane Filters](https://analyt-mtc.com/catalog/product/silver-membrane-filters/)
    
    Pure metallic-silver media, inert to 500 °C — for X-ray diffraction of silica and stack sampling.
    
    0.45–0.8 µm · 25–47 mm
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/silver-membrane-filters/)
    
-     ![](https://analyt-mtc.com/illustrations/glass-fibre-depth-filters.webp)
    
    ### [Glass Fibre Depth Filters](https://analyt-mtc.com/catalog/product/glass-fibre-depth-filters/)
    
    Binder-free borosilicate depth media for high-flow gravimetric sampling; 1.0 µm nominal, autoclavable.
    
    1.0 µm nom. · 13–90 mm · glass
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/glass-fibre-depth-filters/)
    
-     ![](https://analyt-mtc.com/illustrations/quartz-depth-filters.webp)
    
    ### [Quartz Depth Filters](https://analyt-mtc.com/catalog/product/quartz-depth-filters/)
    
    Heat-treated quartz for elemental/organic carbon and diesel particulate (NIOSH 5040); withstands 1000 °C.
    
    1.2 µm nom. · 25–102 mm
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/quartz-depth-filters/)
    
-     ![](https://analyt-mtc.com/illustrations/cellulose-depth-filters.webp)
    
    ### [Cellulose Depth Filters](https://analyt-mtc.com/catalog/product/cellulose-depth-filters/)
    
    100% pure ashless cellulose (Whatman Type 40 equivalent) for ashless gravimetric and AA/HPLC methods.
    
    37 mm · ashless · Type 40
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/cellulose-depth-filters/)
    
-     ![](https://analyt-mtc.com/illustrations/gelatin-filters.webp)
    
    ### [Gelatin Filters](https://analyt-mtc.com/catalog/product/gelatin-filters/)
    
    Water-soluble gelatin that keeps microbes viable and dissolves on agar; 3 µm nominal for bioaerosols.
    
    3 µm nom. · 25 & 37 mm
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/gelatin-filters/)
    
-     ![](https://analyt-mtc.com/illustrations/bestchek-asbestos-cassettes.webp)
    
    ### [BestChek Asbestos Cassettes](https://analyt-mtc.com/catalog/product/bestchek-asbestos-cassettes/)
    
    Preloaded MCE cassettes quality-tested for low fibre background; PCM/TEM asbestos with certificate.
    
    0.45–1.2 µm MCE · 25–37 mm
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/bestchek-asbestos-cassettes/)
    
-     ![](https://analyt-mtc.com/illustrations/iso-chek-cassettes.webp)
    
    ### [ISO-CHEK Cassettes](https://analyt-mtc.com/catalog/product/iso-chek-cassettes/)
    
    Dual-filter cassette that traps isocyanate aerosol and vapour at once; MAMA-coated, 1 L/min for 15 min.
    
    5 µm PTFE + GF · 1 L/min
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/iso-chek-cassettes/)
    
-     ![](https://analyt-mtc.com/illustrations/versatrap-spore-trap-cassette.webp)
    
    ### [VersaTrap Spore Trap Cassette](https://analyt-mtc.com/catalog/product/versatrap-spore-trap-cassette/)
    
    Slide-based spore trap; flow sets the 1.5–3.9 µm cut-point for mould counting (ASTM D7391).
    
    1.5–3.9 µm cut · 5–30 L/min
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/versatrap-spore-trap-cassette/)
    

## [Particle Size-Selective Sampling](https://analyt-mtc.com/catalog/particle-size-selective-sampling/)

15 models

-     ![](https://analyt-mtc.com/illustrations/diesel-particulate-matter-dpm-cyclone.webp)
    
    ### [Diesel Particulate Matter (DPM) Cyclone](https://analyt-mtc.com/catalog/product/diesel-particulate-matter-dpm-cyclone/)
    
    Separates diesel elemental carbon from coal and respirable dust for NIOSH 5040 analysis.
    
    2 L/min · NIOSH 5040
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/diesel-particulate-matter-dpm-cyclone/)
    
-     ![](https://analyt-mtc.com/illustrations/iom-sampler.webp)
    
    ### [IOM Sampler](https://analyt-mtc.com/catalog/product/iom-sampler/)
    
    Reusable weighable cassette traps the inhalable fraction to 100 µm; foam insert adds respirable.
    
    2 L/min · 100 µm · inhalable
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/iom-sampler/)
    
-     ![](https://analyt-mtc.com/illustrations/button-sampler.webp)
    
    ### [Button Sampler](https://analyt-mtc.com/catalog/product/button-sampler/)
    
    Porous curved-surface inlet samples inhalable dust and bioaerosols with low wind sensitivity.
    
    4 L/min · 100 µm · inhalable
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/button-sampler/)
    
-     ![](https://analyt-mtc.com/illustrations/face-level-sampling.webp)
    
    ### [Face Level Sampling](https://analyt-mtc.com/catalog/product/face-level-sampling/)
    
    Dual-arm headset samples welding fume inside masks and helmets to ISO 10882-1.
    
    13 mm MCE · inhalable
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/face-level-sampling/)
    
-     ![](https://analyt-mtc.com/illustrations/plastic-cyclone.webp)
    
    ### [Plastic Cyclone](https://analyt-mtc.com/catalog/product/plastic-cyclone/)
    
    Conductive-plastic respirable cyclone at 3.0 L/min; grit pot and reusable 25 or 37 mm cassette.
    
    3.0 L/min · 4 µm · respirable
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/plastic-cyclone/)
    
-     ![](https://analyt-mtc.com/illustrations/gs-3-respirable-dust-cyclone.webp)
    
    ### [GS-3 Respirable Dust Cyclone](https://analyt-mtc.com/catalog/product/gs-3-respirable-dust-cyclone/)
    
    Multi-inlet respirable cyclone unaffected by wind; 4 µm cut at 2.75 L/min into 25 or 37 mm cassette.
    
    2.75 L/min · 4 µm · respirable
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/gs-3-respirable-dust-cyclone/)
    
-     ![](https://analyt-mtc.com/illustrations/gs-1-respirable-dust-cyclone.webp)
    
    ### [GS-1 Respirable Dust Cyclone](https://analyt-mtc.com/catalog/product/gs-1-respirable-dust-cyclone/)
    
    Single-inlet Dorr-Oliver-equivalent cyclone at 2 L/min; also runs the DPM cassette.
    
    2 L/min · 4 µm · respirable
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/gs-1-respirable-dust-cyclone/)
    
-     ![](https://analyt-mtc.com/illustrations/aluminium-respirable-dust-cyclone.webp)
    
    ### [Aluminium Respirable Dust Cyclone](https://analyt-mtc.com/catalog/product/aluminium-respirable-dust-cyclone/)
    
    Aluminium cyclone with sharp respirable cut for NIOSH 7500 silica; 25 and 37 mm versions.
    
    2.5 L/min · 4 µm · respirable
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/aluminium-respirable-dust-cyclone/)
    
-     ![](https://analyt-mtc.com/illustrations/asbestos-sampling.webp)
    
    ### [Asbestos Sampling](https://analyt-mtc.com/catalog/product/asbestos-sampling/)
    
    Cowled sampling head with 25 mm gridded filter for asbestos fibre counting; plastic or aluminium cowl.
    
    25 mm · 0.8 µm MCE · fibres
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/asbestos-sampling/)
    
-     ![](https://analyt-mtc.com/illustrations/parallel-particle-impactors-ppis.webp)
    
    ### [Parallel Particle Impactors (PPIs)](https://analyt-mtc.com/catalog/product/parallel-particle-impactors-ppis/)
    
    Four impactors in one unit match the respirable or thoracic convention; 2, 4 or 8 L/min models.
    
    2–8 L/min · resp./thoracic
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/parallel-particle-impactors-ppis/)
    
-     ![](https://analyt-mtc.com/illustrations/personal-environmental-monitor-pem.webp)
    
    ### [Personal Environmental Monitor (PEM)](https://analyt-mtc.com/catalog/product/personal-environmental-monitor-pem/)
    
    Impaction sampler for PM2.5 or PM10 indoor air; three flow versions at 2, 4 or 10 L/min.
    
    PM2.5/PM10 · 2, 4, 10 L/min
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/personal-environmental-monitor-pem/)
    
-     ![](https://analyt-mtc.com/illustrations/personal-modular-impactor-pmi.webp)
    
    ### [Personal Modular Impactor (PMI)](https://analyt-mtc.com/catalog/product/personal-modular-impactor-pmi/)
    
    Modular single-stage impactor for PM2.5, PM10 or PM Coarse at 3 L/min; weighs only 71 g.
    
    3 L/min · PM2.5/PM10/Coarse
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/personal-modular-impactor-pmi/)
    
-     ![](https://analyt-mtc.com/illustrations/impact-sampler.webp)
    
    ### [IMPACT Sampler](https://analyt-mtc.com/catalog/product/impact-sampler/)
    
    Ambient PM2.5, PM10 or PM Coarse impactor at 10 L/min onto a 47 mm filter, with rain cover.
    
    10 L/min · PM2.5/PM10 · 47 mm
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/impact-sampler/)
    
-     ![](https://analyt-mtc.com/illustrations/sioutas-personal-cascade-impactor.webp)
    
    ### [Sioutas Personal Cascade Impactor](https://analyt-mtc.com/catalog/product/sioutas-personal-cascade-impactor/)
    
    Cascade impactor collects five size fractions (2.5 to 0.25 µm) at 9 L/min without impaction grease.
    
    9 L/min · 5 stages to 0.25 µm
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/sioutas-personal-cascade-impactor/)
    
-     ![](https://analyt-mtc.com/illustrations/ifv-pro-sampler.webp)
    
    ### [IFV Pro Sampler](https://analyt-mtc.com/catalog/product/ifv-pro-sampler/)
    
    Collects inhalable aerosol and vapour together at 1 L/min for mixed-phase compounds; meets EN 13936.
    
    1 L/min · inhalable + vapour
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/ifv-pro-sampler/)
    

## [Particulate Monitors](https://analyt-mtc.com/catalog/particulate-monitors/)

7 models

-     ![](https://analyt-mtc.com/illustrations/haz-dust-iv-particulate-monitor.webp)
    
    ### [HAZ-DUST IV Particulate Monitor](https://analyt-mtc.com/catalog/product/haz-dust-iv-particulate-monitor/)
    
    Personal real-time monitor with interchangeable heads and an in-line 37 mm cassette for gravimetric back-up.
    
    0.01–200 mg/m³ · 0.1–100 µm
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/haz-dust-iv-particulate-monitor/)
    
-     ![](https://analyt-mtc.com/illustrations/haz-dust-7204-particulate-monitor.webp)
    
    ### [HAZ-DUST 7204 Particulate Monitor](https://analyt-mtc.com/catalog/product/haz-dust-7204-particulate-monitor/)
    
    Combines a gravimetric sampling pump and optical sensor with a colour touch screen; runs over 22 hours.
    
    0.001–500 mg/m³ · 22 h
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/haz-dust-7204-particulate-monitor/)
    
-     ![](https://analyt-mtc.com/illustrations/split2-particulate-monitor.webp)
    
    ### [Split2 Particulate Monitor](https://analyt-mtc.com/catalog/product/split2-particulate-monitor/)
    
    Passive dust monitor that becomes an active gravimetric sampler when paired with a 2 L/min pump.
    
    0.01–200 mg/m³ · 2 L/min
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/split2-particulate-monitor/)
    
-     ![](https://analyt-mtc.com/illustrations/haz-dust-i-particulate-monitor.webp)
    
    ### [HAZ-DUST I Particulate Monitor](https://analyt-mtc.com/catalog/product/haz-dust-i-particulate-monitor/)
    
    Simple handheld survey tool giving instantaneous respirable dust readings on two selectable ranges.
    
    0.01–200 mg/m³ · 0.1–50 µm
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/haz-dust-i-particulate-monitor/)
    
-     ![](https://analyt-mtc.com/illustrations/epam-5000-particulate-monitor.webp)
    
    ### [EPAM 5000 Particulate Monitor](https://analyt-mtc.com/catalog/product/epam-5000-particulate-monitor/)
    
    Weatherproof ambient monitor with interchangeable PM10, PM2.5, PM1.0 and TSP heads; runs up to 24 hours.
    
    0.001–20 mg/m³ · 4 L/min
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/epam-5000-particulate-monitor/)
    
-     ![](https://analyt-mtc.com/illustrations/air-aide-particulate-monitor.webp)
    
    ### [AIR-AIDE Particulate Monitor](https://analyt-mtc.com/catalog/product/air-aide-particulate-monitor/)
    
    Fixed-point monitor with interchangeable PM1, PM2.5, respirable and PM10 impactors at 2 L/min.
    
    0.001–20 mg/m³ · 2 L/min
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/air-aide-particulate-monitor/)
    
-     ![](https://analyt-mtc.com/illustrations/haz-scanner-epas-air-monitoring-station.webp)
    
    ### [HAZ-SCANNER EPAS Monitoring Station](https://analyt-mtc.com/catalog/product/haz-scanner-epas-air-monitoring-station/)
    
    Multi-sensor perimeter station measuring PM10 and PM2.5 plus up to 14 air parameters simultaneously.
    
    Up to 14 sensors · 1–3 L/min
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/haz-scanner-epas-air-monitoring-station/)
    

## Particulate Sampling

1 model

-     ![](https://analyt-mtc.com/illustrations/disposable-parallel-particle-impactors.webp)
    
    ### [Disposable Parallel Particle Impactors](https://analyt-mtc.com/catalog/product/disposable-parallel-particle-impactors/)
    
    Single-use four-impactor sampler for respirable or thoracic PM at 2, 4 or 8 L/min; gravimetric or chemical.
    
    37 mm filter · 2/4/8 L/min
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/disposable-parallel-particle-impactors/)
    

## How do I choose a particulate sampler for airborne dust?

Start from the result you need: a mass concentration for a defined size fraction, a chemical analysis, or an instant reading. For gravimetric or chemical work the sample goes onto a filter. The [filters and cassettes](https://analyt-mtc.com/catalog/filters-and-cassettes/) range covers membrane and depth media, 13 to 102 mm diameters, 0.3 to 10 µm pore sizes; pick the material and pore for your analyte. [Filter and cassettes accessories](https://analyt-mtc.com/catalog/filter-and-cassettes-accessories/) add holders, supports, blanks and storage, but no filter media.

## Which size fraction do I sample: respirable, thoracic or inhalable?

Airborne dust sampling is usually specified by size fraction. [Particle size-selective sampling](https://analyt-mtc.com/catalog/particle-size-selective-sampling/) uses cyclones, impactors and cowled inlets to separate the fraction onto the filter: respirable with a 50% cut-point of 4 µm, inhalable to 100 µm (IOM, Button), and PM10, PM2.5 and PM1.0 impactors. For respirable or thoracic PM, the [disposable parallel particle impactors](https://analyt-mtc.com/catalog/product/disposable-parallel-particle-impactors/) are a single-use four-impactor sampler at 2, 4 or 8 L/min.

## Do I need a direct-reading dust sampler or monitor?

When you want instant values without a lab weighing step, use [particulate monitors](https://analyt-mtc.com/catalog/particulate-monitors/). They read concentration from 0.001 to 500 mg/m³ by optical light-scattering, with ±10% to gravimetric, and show instantaneous, TWA, STEL, min and max values.

## Questions about these products?

Our application engineers aim to reply within 3 business hours.