# Gas And Vapour Sampling

Gas and vapour sampling media collect airborne gases and vapours for later laboratory analysis. The family spans pumped sorbent tubes, diffusive passive samplers, liquid impingers and whole-air sample bags, plus reagent-coated filters for reactive compounds — from SKC.

![SKC](https://analyt-mtc.com/_astro/skc.Bk3xP0Oj.svg)![SKC](https://analyt-mtc.com/_astro/skc-white.bbpzr2g0.svg)

Choose your technology

  ![](https://analyt-mtc.com/illustrations/skc-impingers.webp)

## [Impingers](https://analyt-mtc.com/catalog/impingers/)

Absorb reactive gases and mists into a collection liquid.

1 model

  ![](https://analyt-mtc.com/illustrations/skc-organic-vapour-passive-samplers.webp)

## [Passive Samplers](https://analyt-mtc.com/catalog/passive-samplers/)

No pump: diffusive badges sampling at a fixed uptake rate.

10 models

  ![](https://analyt-mtc.com/illustrations/skc-tedlar-sample-bags.webp)

## [Sample Bags](https://analyt-mtc.com/catalog/sample-bags/)

Hold a whole-air grab sample intact for later lab analysis.

6 models

  ![](https://analyt-mtc.com/illustrations/skc-silica-gel-sorbent-tubes.webp)

## [Sorbent tubes](https://analyt-mtc.com/catalog/sorbent-tubes/)

Pumped sampling drawn through a packed sorbent bed; solvent or thermal desorption.

14 models

## [Impingers](https://analyt-mtc.com/catalog/impingers/)

1 model

-     ![](https://analyt-mtc.com/illustrations/skc-impingers.webp)
    
    ### [Impingers](https://analyt-mtc.com/catalog/product/skc-impingers/)
    
    Glass and PFA bubbler bottles drawing air through a liquid; 25 mL midget, fritted or spill-resistant.
    
    25 mL · 170–200 µm frit
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-impingers/)
    

## [Passive Samplers](https://analyt-mtc.com/catalog/passive-samplers/)

10 models

-     ![](https://analyt-mtc.com/illustrations/skc-organic-vapour-passive-samplers.webp)
    
    ### [Organic Vapour Passive Samplers](https://analyt-mtc.com/catalog/product/skc-organic-vapour-passive-samplers/)
    
    Broadband VOC Chek 575 badge with sampling rates for 300+ compounds; choice of charcoal or Anasorb 747.
    
    350 mg charcoal · 300+ VOCs
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-organic-vapour-passive-samplers/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-ultra-passive-samplers.webp)
    
    ### [ULTRA Passive Samplers](https://analyt-mtc.com/catalog/product/skc-ultra-passive-samplers/)
    
    Diffusive sampler for sub-ppb to ppt VOCs and SVOCs; a pump-free thermal-desorption alternative to EPA TO-17.
    
    5 sorbents · sub-ppb to ppt
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-ultra-passive-samplers/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-umex-100-passive-sampler-for-formaldehyde.webp)
    
    ### [UMEX100 Passive Sampler CH2O](https://analyt-mtc.com/catalog/product/skc-umex-100-passive-sampler-for-formaldehyde/)
    
    Single-use badge for formaldehyde and aldehydes using 2,4-DNPH chemistry; meets OSHA 1007 and ISO 16000-4.
    
    28.6 mL/min · LOD 2 ppb
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-umex-100-passive-sampler-for-formaldehyde/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-umex-200-passive-sampler-so2-no2.webp)
    
    ### [UMEx 200 Passive Sampler SO2/NO2](https://analyt-mtc.com/catalog/product/skc-umex-200-passive-sampler-so2-no2/)
    
    Single-use badge for sulphur dioxide and/or nitrogen dioxide; TEA chemistry as in active OSHA ID-182.
    
    SO2 15.2 · NO2 17.3 mL/min
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-umex-200-passive-sampler-so2-no2/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-umex-300-passive-sampler-ammonia.webp)
    
    ### [UMEx 300 Passive Sampler Ammonia](https://analyt-mtc.com/catalog/product/skc-umex-300-passive-sampler-ammonia/)
    
    Single-use ammonia badge with sulphuric-acid tape; chemistry as in OSHA ID-188 and NIOSH 6016, 0.1–100 ppm.
    
    39.92 mL/min · 0.1–100 ppm
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-umex-300-passive-sampler-ammonia/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-ethylene-oxide-passive-samplers.webp)
    
    ### [Ethylene Oxide Passive Samplers](https://analyt-mtc.com/catalog/product/skc-ethylene-oxide-passive-samplers/)
    
    Ethylene oxide badge using the same sorbent as active OSHA 1010; ideal for hospitals and sterile-supply sites.
    
    21.2 mL/min · 0.1–4 ppm
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-ethylene-oxide-passive-samplers/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-hydrogen-cyanide-passive-samplers.webp)
    
    ### [Hydrogen Cyanide Passive Samplers](https://analyt-mtc.com/catalog/product/skc-hydrogen-cyanide-passive-samplers/)
    
    Miniature HCN badge specified in OSHA Method 1015; soda-lime sorbent loads from a vial in the field.
    
    28.4 mL/min · 0.44–20 ppm
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-hydrogen-cyanide-passive-samplers/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-elemental-mercury-passive-sampler.webp)
    
    ### [Elemental Mercury Passive Sampler](https://analyt-mtc.com/catalog/product/skc-elemental-mercury-passive-sampler/)
    
    Reusable-holder badge for elemental mercury vapour (TWA); Anasorb C300 capsule, validated to OSHA ID-140.
    
    Anasorb C300 · up to 120 h
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-elemental-mercury-passive-sampler/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-ozone-test-strips.webp)
    
    ### [Ozone Test Strips](https://analyt-mtc.com/catalog/product/skc-ozone-test-strips/)
    
    Colour-change strips giving a 10-minute visual read of ozone from under 45 to over 105 ppb — no pump or lab.
    
    45–105 ppb · 10-min read
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-ozone-test-strips/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-passive-thermal-desorption-tubes-2.webp)
    
    ### [Passive Thermal Desorption Tubes](https://analyt-mtc.com/catalog/product/skc-passive-thermal-desorption-tubes-2/)
    
    Pump-free diffusive TD tube for outdoor benzene and VOC monitoring; sorbent Carbopack X or Anasorb GCB1.
    
    Carbopack X/GCB1 · EPA 325A
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-passive-thermal-desorption-tubes-2/)
    

## [Sample Bags](https://analyt-mtc.com/catalog/sample-bags/)

6 models

-     ![](https://analyt-mtc.com/illustrations/skc-tedlar-sample-bags.webp)
    
    ### [Tedlar Sample Bags](https://analyt-mtc.com/catalog/product/skc-tedlar-sample-bags/)
    
    Classic 51 µm Tedlar film for VOCs, referenced in many EPA methods; rated -72 to 107 °C in 0.5 to 100 L sizes.
    
    51 µm · -72 to 107 °C
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-tedlar-sample-bags/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-flexfoil-plus-sample-bags.webp)
    
    ### [FlexFoil PLUS Sample Bags](https://analyt-mtc.com/catalog/product/skc-flexfoil-plus-sample-bags/)
    
    Specially cleaned 4-ply 127 µm foil, low VOC and sulphur background; good stability for low-ppm VOCs.
    
    4-ply · 127 µm · 48-h H2S
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-flexfoil-plus-sample-bags/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-breath-gas-analysis-bags.webp)
    
    ### [Breath-gas Analysis Bags](https://analyt-mtc.com/catalog/product/skc-breath-gas-analysis-bags/)
    
    Bags with a low-resistance mouthpiece fitting for human-breath VOC and VSC sampling; Tedlar or FlexFoil PLUS.
    
    1 L · Tedlar/FlexFoil PLUS
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-breath-gas-analysis-bags/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-vac-u-chamber.webp)
    
    ### [SKC Vac-U-Chamber](https://analyt-mtc.com/catalog/product/skc-vac-u-chamber/)
    
    Rigid box that fills a sample bag by vacuum so the sample never passes through the pump; for 1 to 25 L bags.
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-vac-u-chamber/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-custom-sample-bags.webp)
    
    ### [Custom Sample Bags](https://analyt-mtc.com/catalog/product/skc-custom-sample-bags/)
    
    Made-to-order bags in any material — Tedlar, FlexFilm or FlexFoil — with your choice of size and fitting.
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-custom-sample-bags/)
    
-     ![](https://analyt-mtc.com/illustrations/standard-flexfoil-sample-bags-2.webp)
    
    ### [Standard FlexFoil Sample Bags](https://analyt-mtc.com/catalog/product/standard-flexfoil-sample-bags-2/)
    
    Economical 4-ply 127 µm foil for VOCs, CO, CO2, methane and SF6; low sulphur background, 48-h H2S stability.
    
    4-ply · 127 µm · low sulphur
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/standard-flexfoil-sample-bags-2/)
    

## [Sorbent tubes](https://analyt-mtc.com/catalog/sorbent-tubes/)

14 models

-     ![](https://analyt-mtc.com/illustrations/skc-silica-gel-sorbent-tubes.webp)
    
    ### [Silica Gel Sorbent Tubes](https://analyt-mtc.com/catalog/product/skc-silica-gel-sorbent-tubes/)
    
    Polar sorbent for methanol, amines, acids and mercaptans; treated grades collect aldehydes and ammonia.
    
    Silica gel · 6–10 mm OD
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-silica-gel-sorbent-tubes/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-anasorb-sorbent-tubes.webp)
    
    ### [Anasorb Sorbent Tubes](https://analyt-mtc.com/catalog/product/skc-anasorb-sorbent-tubes/)
    
    SKC proprietary sorbents: 747 carbon for polar organics and ketones, plus CSC charcoal and GCB grades.
    
    Anasorb 747 / CSC / GCB
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-anasorb-sorbent-tubes/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-charcoal-sorbent-tubes.webp)
    
    ### [Charcoal Sorbent Tubes](https://analyt-mtc.com/catalog/product/skc-charcoal-sorbent-tubes/)
    
    Coconut-shell charcoal, high surface area for a broad range of non-polar organic vapours.
    
    Coconut charcoal · 6–10 mm OD
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-charcoal-sorbent-tubes/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-tenax-sorbent-tubes.webp)
    
    ### [Tenax Sorbent Tubes](https://analyt-mtc.com/catalog/product/skc-tenax-sorbent-tubes/)
    
    Porous-polymer sorbent for mid-to-high-boiling compounds; low background, hydrophobic, for thermal desorption.
    
    Tenax TA & GR · EPA TO-17
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-tenax-sorbent-tubes/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-xad-sorbent-tubes.webp)
    
    ### [XAD Sorbent Tubes](https://analyt-mtc.com/catalog/product/skc-xad-sorbent-tubes/)
    
    Hydrophobic porous-polymer resin XAD-2/4/7 for soluble organics and pesticides; many coated variants.
    
    XAD-2, XAD-4, XAD-7
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-xad-sorbent-tubes/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-chromosorb-sorbent-tubes.webp)
    
    ### [Chromosorb Sorbent Tubes](https://analyt-mtc.com/catalog/product/skc-chromosorb-sorbent-tubes/)
    
    Porous polymer for low-boiling hydrocarbons and benzene; grade 102 traps chlorinated pesticides.
    
    Chromosorb 102 / 106
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-chromosorb-sorbent-tubes/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-polyurethane-foam-puf-tubes.webp)
    
    ### [Polyurethane Foam (PUF) Tubes](https://analyt-mtc.com/catalog/product/skc-polyurethane-foam-puf-tubes/)
    
    Foam plugs for semi-volatiles: low-volume tubes to 24 h or high-volume tubes for ambient PCBs and PAHs.
    
    22×100 or 65×125 mm
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-polyurethane-foam-puf-tubes/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-porapak-sorbent-tubes.webp)
    
    ### [Porapak Sorbent Tubes](https://analyt-mtc.com/catalog/product/skc-porapak-sorbent-tubes/)
    
    Porous polymers of graded polarity (P, Q, T, N); the N grade is used to monitor volatile nitriles.
    
    Porapak P, Q, T, N
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-porapak-sorbent-tubes/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-osha-versatile-sampler-ovs-tubes.webp)
    
    ### [OSHA Versatile Sampler (OVS) Tubes](https://analyt-mtc.com/catalog/product/skc-osha-versatile-sampler-ovs-tubes/)
    
    Combined filter and two-bed sorbent tube collecting aerosols and vapours — pesticides, explosives, glycols.
    
    Filter + 2 sorbent beds
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-osha-versatile-sampler-ovs-tubes/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-thermal-desorption-sorbent-tubes.webp)
    
    ### [Thermal Desorption Sorbent Tubes](https://analyt-mtc.com/catalog/product/skc-thermal-desorption-sorbent-tubes/)
    
    Single- and multi-bed tubes for sub-ppb VOCs in ambient air; purged or unpurged, EPA and MDHS methods.
    
    ¼ × 3½ in · EPA/MDHS
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-thermal-desorption-sorbent-tubes/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-passive-thermal-desorption-tubes.webp)
    
    ### [Passive Thermal Desorption Tubes](https://analyt-mtc.com/catalog/product/skc-passive-thermal-desorption-tubes/)
    
    Diffusive stainless steel TD tubes for 14-day fenceline benzene monitoring; meet EPA 325A and MDHS 104.
    
    89 × 6.35 mm · EPA 325A
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-passive-thermal-desorption-tubes/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-specific-sorbent-tubes.webp)
    
    ### [Specific Sorbent Tubes](https://analyt-mtc.com/catalog/product/skc-specific-sorbent-tubes/)
    
    Niche sorbents in one range: carbon beads, Florisil, molecular sieve, firebrick, soda lime and VOST traps.
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-specific-sorbent-tubes/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-custom-sorbent-tubes.webp)
    
    ### [Custom Sorbent Tubes](https://analyt-mtc.com/catalog/product/skc-custom-sorbent-tubes/)
    
    Made-to-order solvent- and thermal-desorption tubes built to your sorbent, size and packing specification.
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-custom-sorbent-tubes/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-gas-and-vapour-sampling-accessories.webp)
    
    ### [Gas and Vapour Sampling Accessories](https://analyt-mtc.com/catalog/product/skc-gas-and-vapour-sampling-accessories/)
    
    Sampling-train hardware: low-flow adaptors and CPCs, tube holders and covers, tube breakers and field tools.
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-gas-and-vapour-sampling-accessories/)
    

## Gas And Vapour Sampling

1 model

-     ![](https://analyt-mtc.com/illustrations/skc-coated-treated-filters.webp)
    
    ### [Coated (Treated) Filters](https://analyt-mtc.com/catalog/product/skc-coated-treated-filters/)
    
    Reagent-coated filters preloaded in cassettes to trap aldehydes, amines and acids without impinger liquids.
    
    37 mm cassette · packs of 10
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-coated-treated-filters/)
    

## How do I sample vapours with a sorbent tube and pump?

[Sorbent tubes](https://analyt-mtc.com/catalog/sorbent-tubes/) are the standard route for organic vapour sampling, including charcoal tube sampling. A pump draws air through a packed sorbent bed, and the trapped vapours are recovered by solvent or thermal desorption for GC or HPLC. Sorbents span charcoal, silica gel, Anasorb, Tenax and XAD, and the tubes meet OSHA, NIOSH, EPA TO-17 and MDHS methods. Choose the sorbent for your analyte and the desorption format for your laboratory.

## Can I sample gases and vapours without a pump?

Yes. [Passive samplers](https://analyt-mtc.com/catalog/passive-samplers/) collect by diffusion at a validated uptake rate, 15 to 40 mL/min, and are validated to ASTM D6246 and ANSI/ISEA 104. Sampling runs from 15 minutes to 7 days. Besides broadband organic-vapour badges, there are compound-specific samplers for formaldehyde, SO2/NO2, ammonia and ozone, among others.

## Which medium suits reactive gases, mists or a grab sample?

For reactive gases and mists, [impingers](https://analyt-mtc.com/catalog/impingers/) draw air through a collection liquid for wet-chemistry analysis. To keep a whole-air grab sample intact, use [sample bags](https://analyt-mtc.com/catalog/sample-bags/), in sizes from 0.5 to 100 litres. For aldehydes, amines and acids without impinger liquids, the [coated (treated) filters](https://analyt-mtc.com/catalog/product/skc-coated-treated-filters/) come preloaded in cassettes with a reagent coating.

## Questions about these products?

Our application engineers aim to reply within 3 business hours.

[Ask an engineer](https://analyt-mtc.com/contact/?ask=1)