# Air Sampling Pumps

Air sampling pumps are battery-powered units that draw air through filters, cassettes or sorbent tubes for workplace exposure sampling. The range spans personal low-flow pumps from 5 ml/min to high-volume units for 20 L/min and above, with matching sampling kits, software and low-flow accessories — from SKC.

![SKC](https://analyt-mtc.com/_astro/skc.Bk3xP0Oj.svg)![SKC](https://analyt-mtc.com/_astro/skc-white.bbpzr2g0.svg)

Choose your technology

  ![](https://analyt-mtc.com/illustrations/skc-biolite-pump.webp)

## [Air Sampling Pumps Above 5 L/min](https://analyt-mtc.com/catalog/air-sampling-pumps-above-5-l-min/)

High-volume area, asbestos and bioaerosol sampling from 5 to 62 L/min.

3 models

  ![](https://analyt-mtc.com/illustrations/basic-sampling-kits.webp)

## [Air Sampling Kits](https://analyt-mtc.com/catalog/air-sampling-kits-en/)

Pump plus method accessories in one case — dust, vapour or both.

4 models

  ![](https://analyt-mtc.com/illustrations/skc-airchek-connect-pump.webp)

## [Air Sampling Pumps Up To 5 L/min](https://analyt-mtc.com/catalog/air-sampling-pumps-up-to-5-l-min/)

Belt-worn personal sampling to 5 L/min — dust, vapour and sorbent tubes.

10 models

  ![](https://analyt-mtc.com/illustrations/datatrac-software.webp)

## [Software And Accessories](https://analyt-mtc.com/catalog/software-and-accessories/)

Add PC pump control or low-flow (5–500 ml/min) sorbent-tube sampling.

2 models

## [Air Sampling Pumps Above 5 L/min](https://analyt-mtc.com/catalog/air-sampling-pumps-above-5-l-min/)

3 models

-     ![](https://analyt-mtc.com/illustrations/skc-biolite-pump.webp)
    
    ### [BioLite+ Pump](https://analyt-mtc.com/catalog/product/skc-biolite-pump/)
    
    Mains bioaerosol pump to 62 L/min for BioSampler liquid impingement; two mounts run two samplers.
    
    to 62 L/min · mains · 7.25 kg
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-biolite-pump/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-flite4-pump.webp)
    
    ### [Flite 4 Pump](https://analyt-mtc.com/catalog/product/skc-flite4-pump/)
    
    High-volume pump, 2–20 L/min for asbestos and area monitoring; battery or AC, programmable timer.
    
    2–20 L/min · battery/AC
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-flite4-pump/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-leland-legacy-pump.webp)
    
    ### [Leland Legacy Pump](https://analyt-mtc.com/catalog/product/skc-leland-legacy-pump/)
    
    Battery high-flow pump, 5–15 L/min; Li-ion for 24+ hours at 5 L/min, ideal for unattended sampling.
    
    5–15 L/min · 24+ h · Li-ion
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-leland-legacy-pump/)
    

## [Air Sampling Kits](https://analyt-mtc.com/catalog/air-sampling-kits-en/)

4 models

-     ![](https://analyt-mtc.com/illustrations/basic-sampling-kits.webp)
    
    ### [Basic Sampling Kits](https://analyt-mtc.com/catalog/product/basic-sampling-kits/)
    
    Pump-only starter kit — charger, tubing, screwdriver set and case; add your own sampling media.
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/basic-sampling-kits/)
    
-     ![](https://analyt-mtc.com/illustrations/dust-sampling-kits.webp)
    
    ### [Dust Sampling Kits](https://analyt-mtc.com/catalog/product/dust-sampling-kits/)
    
    Adds IOM Multidust sampler, cassettes and foams for inhalable or respirable dust; media separate.
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/dust-sampling-kits/)
    
-     ![](https://analyt-mtc.com/illustrations/vapour-gas-sampling-kits.webp)
    
    ### [Vapour/Gas Sampling Kits](https://analyt-mtc.com/catalog/product/vapour-gas-sampling-kits/)
    
    Adds sorbent-tube holder, constant-pressure controller and cover for gas and vapour; tubes separate.
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/vapour-gas-sampling-kits/)
    
-     ![](https://analyt-mtc.com/illustrations/combined-dust-vapour-sampling-kits.webp)
    
    ### [Combined Dust/Vapour Sampling Kits](https://analyt-mtc.com/catalog/product/combined-dust-vapour-sampling-kits/)
    
    Combines dust cassettes and sorbent-tube holders for sites needing both methods; media separate.
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/combined-dust-vapour-sampling-kits/)
    

## [Air Sampling Pumps Up To 5 L/min](https://analyt-mtc.com/catalog/air-sampling-pumps-up-to-5-l-min/)

10 models

-     ![](https://analyt-mtc.com/illustrations/skc-airchek-connect-pump.webp)
    
    ### [AirChek Connect Pump](https://analyt-mtc.com/catalog/product/skc-airchek-connect-pump/)
    
    Bluetooth touchscreen pump with SmartWave app and DataTrac Pro control; Li-ion runs over 40 hours.
    
    5–5000 ml/min · 40 h · Li-ion
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-airchek-connect-pump/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-airchek-essential-pump.webp)
    
    ### [AirChek ESSENTIAL Pump](https://analyt-mtc.com/catalog/product/skc-airchek-essential-pump/)
    
    Low-cost touch-keypad pump for dust and vapour; monochrome display, Li-ion for 40+ hours at 2 L/min.
    
    5–5000 ml/min · 40 h
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-airchek-essential-pump/)
    
-     ![](https://analyt-mtc.com/illustrations/pocket-pump-touch.webp)
    
    ### [Pocket Pump TOUCH](https://analyt-mtc.com/catalog/product/pocket-pump-touch/)
    
    Pocket-sized low-flow pump, 20–500 ml/min for gas and vapour; touchscreen, bag-fill port, 235 g.
    
    20–500 ml/min · 235 g
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/pocket-pump-touch/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-sidekick-pump.webp)
    
    ### [Sidekick Pump](https://analyt-mtc.com/catalog/product/skc-sidekick-pump/)
    
    Rugged NiMH pump, 5–3000 ml/min for dust and gas; Standard, Intermediate and Deluxe, ATEX models.
    
    5–3000 ml/min · NiMH · 465 g
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-sidekick-pump/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-airchek-touch-pump.webp)
    
    ### [AirChek TOUCH Pump](https://analyt-mtc.com/catalog/product/skc-airchek-touch-pump/)
    
    Colour touchscreen pump, 5–5000 ml/min; CalChek auto-calibration and DataTrac Pro programming.
    
    5–5000 ml/min · Li-ion
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-airchek-touch-pump/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-universal-pump.webp)
    
    ### [Universal Pump](https://analyt-mtc.com/catalog/product/skc-universal-pump/)
    
    Metal-cased ATEX pump, 5–4000 ml/min for dust, gas, bag and impinger sampling; timer models.
    
    5–4000 ml/min · ATEX · 915 g
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-universal-pump/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-airchek-xr5000-pump.webp)
    
    ### [AirChek XR5000 Pump](https://analyt-mtc.com/catalog/product/skc-airchek-xr5000-pump/)
    
    Two Li-ion battery options for 40+ hours at 2 L/min; 5–5000 ml/min, built-in low-flow regulator.
    
    5–5000 ml/min · 40+ h
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-airchek-xr5000-pump/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-airlite-pump.webp)
    
    ### [AirLite Pump](https://analyt-mtc.com/catalog/product/skc-airlite-pump/)
    
    Runs on 3 disposable AA alkaline cells, 5–3000 ml/min; 340 g, easy-clean impact-resistant case.
    
    5–3000 ml/min · 3×AA · 340 g
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-airlite-pump/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-airchek-3000-pump.webp)
    
    ### [AirChek 3000 Pump](https://analyt-mtc.com/catalog/product/skc-airchek-3000-pump/)
    
    ATEX and IECEx certified for explosive atmospheres; 5–3250 ml/min, IP64 rubberised case, NiMH.
    
    5–3250 ml/min · IP64 · NiMH
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-airchek-3000-pump/)
    
-     ![](https://analyt-mtc.com/illustrations/sslite-sampling-system.webp)
    
    ### [SSlite Sampling System](https://analyt-mtc.com/catalog/product/sslite-sampling-system/)
    
    Mass-flow sampling system targeting sample volume or mass, 100 ml/min–3 L/min; single or dual channel.
    
    100 ml/min–3 L/min
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/sslite-sampling-system/)
    

## [Software And Accessories](https://analyt-mtc.com/catalog/software-and-accessories/)

2 models

-     ![](https://analyt-mtc.com/illustrations/datatrac-software.webp)
    
    ### [DataTrac® Software](https://analyt-mtc.com/catalog/product/datatrac-software/)
    
    PC software to program pumps, run them remotely and download sampling data for exposure records.
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/datatrac-software/)
    
-     ![](https://analyt-mtc.com/illustrations/low-flow-adaptor-kit.webp)
    
    ### [Low Flow Adaptor Kit](https://analyt-mtc.com/catalog/product/low-flow-adaptor-kit/)
    
    Extends Sidekick and AirChek pumps to 5–500 ml/min for sorbent-tube sampling; tube holder and cover.
    
    5–500 ml/min
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/low-flow-adaptor-kit/)
    

## Which air sampling pump do I need for personal sampling?

For a pump worn on the belt, see [personal sampling pumps](https://analyt-mtc.com/catalog/air-sampling-pumps-up-to-5-l-min/). They hold a constant flow for dust, vapour and gas sampling, and a low-flow adaptor takes them down to the flow rates of sorbent tubes. Several models are intrinsically safe (ATEX) for hazardous areas.

## When is a high-volume pump the right choice?

Area, environmental and asbestos monitoring and bioaerosol collection need more air than a personal pump moves. The [high-volume pumps](https://analyt-mtc.com/catalog/air-sampling-pumps-above-5-l-min/) cover filters, cascade impactors and liquid impingers, with battery or AC-mains models and flows up to 62 L/min. Match the flow to the method: the sampling head and the analytical method define the flow rate, not the other way round.

## Is there a ready-made sampling kit?

[Sampling kits](https://analyt-mtc.com/catalog/air-sampling-kits-en/) pair a pump with the accessories for a given method in a carry case, as pump-only, dust, vapour or combined dust-and-vapour sets. Media are ordered separately. For programming and downloading run data, and for extending pumps to low flows, see [software and accessories](https://analyt-mtc.com/catalog/software-and-accessories/).

## Questions about these products?

Our application engineers aim to reply within 3 business hours.

[Ask an engineer](https://analyt-mtc.com/contact/?ask=1)