title: "Air sampling consumables: media and supplies — Analyt-MTC"
url: https://analyt-mtc.com/catalog/air-sampling-consumables/
lang: en
alternates:
  de: https://analyt-mtc.com/de/catalog/luftprobenahme/
  en: https://analyt-mtc.com/catalog/air-sampling-consumables/
---

# Air Sampling Consumables

Air sampling consumables are the sampling media and accessories for occupational and environmental air monitoring — the medium that captures each contaminant plus the supplies around it. The range spans sorbent tubes and passive samplers for gases and vapours, filter cassettes and cyclones for particulate, liquid impingers and impactors for bioaerosols, and wipes and swabs for surface and skin sampling — mostly from SKC.

![SKC](https://analyt-mtc.com/_astro/skc.Bk3xP0Oj.svg)![SKC](https://analyt-mtc.com/_astro/skc-white.bbpzr2g0.svg)

Choose your technology

  ![](https://analyt-mtc.com/illustrations/skc-biolite-pump.webp)

## [Bioaerosol Samplers](https://analyt-mtc.com/catalog/bioaerosol-samplers/)

Sampling viable, culturable airborne micro-organisms — bacteria, fungi, viruses

3 models

  ![](https://analyt-mtc.com/illustrations/skc-coated-treated-filters.webp)

## [Gas And Vapour Sampling](https://analyt-mtc.com/catalog/gas-and-vapour-sampling/)

For gases and vapours, not particulate, bioaerosol or surface contamination.

32 models

  ![](https://analyt-mtc.com/illustrations/disposable-parallel-particle-impactors.webp)

## [Particulate Sampling](https://analyt-mtc.com/catalog/particulate-sampling/)

Collecting airborne dust, fibres and particulate onto filters or samplers.

42 models

  ![](https://analyt-mtc.com/illustrations/microvacuum-cassettes.webp)

## [Surface & Skin Sampling](https://analyt-mtc.com/catalog/surface-skin-sampling/)

Assessing contamination settled on surfaces and skin, not airborne

17 models

## [Bioaerosol Samplers](https://analyt-mtc.com/catalog/bioaerosol-samplers/)

3 models

-     ![](https://analyt-mtc.com/illustrations/skc-biolite-pump.webp)
    
    ### [BioLite+ Pump](https://analyt-mtc.com/catalog/product/skc-biolite-pump/)
    
    Mains bioaerosol pump to 62 L/min for BioSampler liquid impingement; two mounts run two samplers.
    
    to 62 L/min · mains · 7.25 kg
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-biolite-pump/)
    
-     ![](https://analyt-mtc.com/illustrations/biosampler.webp)
    
    ### [BioSampler](https://analyt-mtc.com/catalog/product/biosampler/)
    
    Glass swirling-liquid impinger collecting into water or ViaTrap oil; autoclavable and reusable for up to 8 h.
    
    12.5 L/min · glass · to 8 h
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/biosampler/)
    
-     ![](https://analyt-mtc.com/illustrations/biostage.webp)
    
    ### [BioStage](https://analyt-mtc.com/catalog/product/biostage/)
    
    Single-stage cascade impactor depositing organisms onto agar plates at 28.3 L/min; meets NIOSH 0800/0801.
    
    28.3 L/min · D50 0.6 µm
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/biostage/)
    

## [Gas And Vapour Sampling](https://analyt-mtc.com/catalog/gas-and-vapour-sampling/)

32 models

-     ![](https://analyt-mtc.com/illustrations/skc-coated-treated-filters.webp)
    
    ### [Coated (Treated) Filters](https://analyt-mtc.com/catalog/product/skc-coated-treated-filters/)
    
    Reagent-coated filters preloaded in cassettes to trap aldehydes, amines and acids without impinger liquids.
    
    37 mm cassette · packs of 10
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-coated-treated-filters/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-impingers.webp)
    
    ### [Impingers](https://analyt-mtc.com/catalog/product/skc-impingers/)
    
    Glass and PFA bubbler bottles drawing air through a liquid; 25 mL midget, fritted or spill-resistant.
    
    25 mL · 170–200 µm frit
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-impingers/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-organic-vapour-passive-samplers.webp)
    
    ### [Organic Vapour Passive Samplers](https://analyt-mtc.com/catalog/product/skc-organic-vapour-passive-samplers/)
    
    Broadband VOC Chek 575 badge with sampling rates for 300+ compounds; choice of charcoal or Anasorb 747.
    
    350 mg charcoal · 300+ VOCs
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-organic-vapour-passive-samplers/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-ultra-passive-samplers.webp)
    
    ### [ULTRA Passive Samplers](https://analyt-mtc.com/catalog/product/skc-ultra-passive-samplers/)
    
    Diffusive sampler for sub-ppb to ppt VOCs and SVOCs; a pump-free thermal-desorption alternative to EPA TO-17.
    
    5 sorbents · sub-ppb to ppt
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-ultra-passive-samplers/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-umex-100-passive-sampler-for-formaldehyde.webp)
    
    ### [UMEX100 Passive Sampler CH2O](https://analyt-mtc.com/catalog/product/skc-umex-100-passive-sampler-for-formaldehyde/)
    
    Single-use badge for formaldehyde and aldehydes using 2,4-DNPH chemistry; meets OSHA 1007 and ISO 16000-4.
    
    28.6 mL/min · LOD 2 ppb
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-umex-100-passive-sampler-for-formaldehyde/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-umex-200-passive-sampler-so2-no2.webp)
    
    ### [UMEx 200 Passive Sampler SO2/NO2](https://analyt-mtc.com/catalog/product/skc-umex-200-passive-sampler-so2-no2/)
    
    Single-use badge for sulphur dioxide and/or nitrogen dioxide; TEA chemistry as in active OSHA ID-182.
    
    SO2 15.2 · NO2 17.3 mL/min
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-umex-200-passive-sampler-so2-no2/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-umex-300-passive-sampler-ammonia.webp)
    
    ### [UMEx 300 Passive Sampler Ammonia](https://analyt-mtc.com/catalog/product/skc-umex-300-passive-sampler-ammonia/)
    
    Single-use ammonia badge with sulphuric-acid tape; chemistry as in OSHA ID-188 and NIOSH 6016, 0.1–100 ppm.
    
    39.92 mL/min · 0.1–100 ppm
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-umex-300-passive-sampler-ammonia/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-ethylene-oxide-passive-samplers.webp)
    
    ### [Ethylene Oxide Passive Samplers](https://analyt-mtc.com/catalog/product/skc-ethylene-oxide-passive-samplers/)
    
    Ethylene oxide badge using the same sorbent as active OSHA 1010; ideal for hospitals and sterile-supply sites.
    
    21.2 mL/min · 0.1–4 ppm
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-ethylene-oxide-passive-samplers/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-hydrogen-cyanide-passive-samplers.webp)
    
    ### [Hydrogen Cyanide Passive Samplers](https://analyt-mtc.com/catalog/product/skc-hydrogen-cyanide-passive-samplers/)
    
    Miniature HCN badge specified in OSHA Method 1015; soda-lime sorbent loads from a vial in the field.
    
    28.4 mL/min · 0.44–20 ppm
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-hydrogen-cyanide-passive-samplers/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-elemental-mercury-passive-sampler.webp)
    
    ### [Elemental Mercury Passive Sampler](https://analyt-mtc.com/catalog/product/skc-elemental-mercury-passive-sampler/)
    
    Reusable-holder badge for elemental mercury vapour (TWA); Anasorb C300 capsule, validated to OSHA ID-140.
    
    Anasorb C300 · up to 120 h
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-elemental-mercury-passive-sampler/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-ozone-test-strips.webp)
    
    ### [Ozone Test Strips](https://analyt-mtc.com/catalog/product/skc-ozone-test-strips/)
    
    Colour-change strips giving a 10-minute visual read of ozone from under 45 to over 105 ppb — no pump or lab.
    
    45–105 ppb · 10-min read
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-ozone-test-strips/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-passive-thermal-desorption-tubes-2.webp)
    
    ### [Passive Thermal Desorption Tubes](https://analyt-mtc.com/catalog/product/skc-passive-thermal-desorption-tubes-2/)
    
    Pump-free diffusive TD tube for outdoor benzene and VOC monitoring; sorbent Carbopack X or Anasorb GCB1.
    
    Carbopack X/GCB1 · EPA 325A
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-passive-thermal-desorption-tubes-2/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-tedlar-sample-bags.webp)
    
    ### [Tedlar Sample Bags](https://analyt-mtc.com/catalog/product/skc-tedlar-sample-bags/)
    
    Classic 51 µm Tedlar film for VOCs, referenced in many EPA methods; rated -72 to 107 °C in 0.5 to 100 L sizes.
    
    51 µm · -72 to 107 °C
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-tedlar-sample-bags/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-flexfoil-plus-sample-bags.webp)
    
    ### [FlexFoil PLUS Sample Bags](https://analyt-mtc.com/catalog/product/skc-flexfoil-plus-sample-bags/)
    
    Specially cleaned 4-ply 127 µm foil, low VOC and sulphur background; good stability for low-ppm VOCs.
    
    4-ply · 127 µm · 48-h H2S
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-flexfoil-plus-sample-bags/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-breath-gas-analysis-bags.webp)
    
    ### [Breath-gas Analysis Bags](https://analyt-mtc.com/catalog/product/skc-breath-gas-analysis-bags/)
    
    Bags with a low-resistance mouthpiece fitting for human-breath VOC and VSC sampling; Tedlar or FlexFoil PLUS.
    
    1 L · Tedlar/FlexFoil PLUS
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-breath-gas-analysis-bags/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-vac-u-chamber.webp)
    
    ### [SKC Vac-U-Chamber](https://analyt-mtc.com/catalog/product/skc-vac-u-chamber/)
    
    Rigid box that fills a sample bag by vacuum so the sample never passes through the pump; for 1 to 25 L bags.
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-vac-u-chamber/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-custom-sample-bags.webp)
    
    ### [Custom Sample Bags](https://analyt-mtc.com/catalog/product/skc-custom-sample-bags/)
    
    Made-to-order bags in any material — Tedlar, FlexFilm or FlexFoil — with your choice of size and fitting.
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-custom-sample-bags/)
    
-     ![](https://analyt-mtc.com/illustrations/standard-flexfoil-sample-bags-2.webp)
    
    ### [Standard FlexFoil Sample Bags](https://analyt-mtc.com/catalog/product/standard-flexfoil-sample-bags-2/)
    
    Economical 4-ply 127 µm foil for VOCs, CO, CO2, methane and SF6; low sulphur background, 48-h H2S stability.
    
    4-ply · 127 µm · low sulphur
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/standard-flexfoil-sample-bags-2/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-silica-gel-sorbent-tubes.webp)
    
    ### [Silica Gel Sorbent Tubes](https://analyt-mtc.com/catalog/product/skc-silica-gel-sorbent-tubes/)
    
    Polar sorbent for methanol, amines, acids and mercaptans; treated grades collect aldehydes and ammonia.
    
    Silica gel · 6–10 mm OD
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-silica-gel-sorbent-tubes/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-anasorb-sorbent-tubes.webp)
    
    ### [Anasorb Sorbent Tubes](https://analyt-mtc.com/catalog/product/skc-anasorb-sorbent-tubes/)
    
    SKC proprietary sorbents: 747 carbon for polar organics and ketones, plus CSC charcoal and GCB grades.
    
    Anasorb 747 / CSC / GCB
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-anasorb-sorbent-tubes/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-charcoal-sorbent-tubes.webp)
    
    ### [Charcoal Sorbent Tubes](https://analyt-mtc.com/catalog/product/skc-charcoal-sorbent-tubes/)
    
    Coconut-shell charcoal, high surface area for a broad range of non-polar organic vapours.
    
    Coconut charcoal · 6–10 mm OD
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-charcoal-sorbent-tubes/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-tenax-sorbent-tubes.webp)
    
    ### [Tenax Sorbent Tubes](https://analyt-mtc.com/catalog/product/skc-tenax-sorbent-tubes/)
    
    Porous-polymer sorbent for mid-to-high-boiling compounds; low background, hydrophobic, for thermal desorption.
    
    Tenax TA & GR · EPA TO-17
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-tenax-sorbent-tubes/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-xad-sorbent-tubes.webp)
    
    ### [XAD Sorbent Tubes](https://analyt-mtc.com/catalog/product/skc-xad-sorbent-tubes/)
    
    Hydrophobic porous-polymer resin XAD-2/4/7 for soluble organics and pesticides; many coated variants.
    
    XAD-2, XAD-4, XAD-7
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-xad-sorbent-tubes/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-chromosorb-sorbent-tubes.webp)
    
    ### [Chromosorb Sorbent Tubes](https://analyt-mtc.com/catalog/product/skc-chromosorb-sorbent-tubes/)
    
    Porous polymer for low-boiling hydrocarbons and benzene; grade 102 traps chlorinated pesticides.
    
    Chromosorb 102 / 106
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-chromosorb-sorbent-tubes/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-polyurethane-foam-puf-tubes.webp)
    
    ### [Polyurethane Foam (PUF) Tubes](https://analyt-mtc.com/catalog/product/skc-polyurethane-foam-puf-tubes/)
    
    Foam plugs for semi-volatiles: low-volume tubes to 24 h or high-volume tubes for ambient PCBs and PAHs.
    
    22×100 or 65×125 mm
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-polyurethane-foam-puf-tubes/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-porapak-sorbent-tubes.webp)
    
    ### [Porapak Sorbent Tubes](https://analyt-mtc.com/catalog/product/skc-porapak-sorbent-tubes/)
    
    Porous polymers of graded polarity (P, Q, T, N); the N grade is used to monitor volatile nitriles.
    
    Porapak P, Q, T, N
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-porapak-sorbent-tubes/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-osha-versatile-sampler-ovs-tubes.webp)
    
    ### [OSHA Versatile Sampler (OVS) Tubes](https://analyt-mtc.com/catalog/product/skc-osha-versatile-sampler-ovs-tubes/)
    
    Combined filter and two-bed sorbent tube collecting aerosols and vapours — pesticides, explosives, glycols.
    
    Filter + 2 sorbent beds
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-osha-versatile-sampler-ovs-tubes/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-thermal-desorption-sorbent-tubes.webp)
    
    ### [Thermal Desorption Sorbent Tubes](https://analyt-mtc.com/catalog/product/skc-thermal-desorption-sorbent-tubes/)
    
    Single- and multi-bed tubes for sub-ppb VOCs in ambient air; purged or unpurged, EPA and MDHS methods.
    
    ¼ × 3½ in · EPA/MDHS
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-thermal-desorption-sorbent-tubes/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-passive-thermal-desorption-tubes.webp)
    
    ### [Passive Thermal Desorption Tubes](https://analyt-mtc.com/catalog/product/skc-passive-thermal-desorption-tubes/)
    
    Diffusive stainless steel TD tubes for 14-day fenceline benzene monitoring; meet EPA 325A and MDHS 104.
    
    89 × 6.35 mm · EPA 325A
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-passive-thermal-desorption-tubes/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-specific-sorbent-tubes.webp)
    
    ### [Specific Sorbent Tubes](https://analyt-mtc.com/catalog/product/skc-specific-sorbent-tubes/)
    
    Niche sorbents in one range: carbon beads, Florisil, molecular sieve, firebrick, soda lime and VOST traps.
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-specific-sorbent-tubes/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-custom-sorbent-tubes.webp)
    
    ### [Custom Sorbent Tubes](https://analyt-mtc.com/catalog/product/skc-custom-sorbent-tubes/)
    
    Made-to-order solvent- and thermal-desorption tubes built to your sorbent, size and packing specification.
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-custom-sorbent-tubes/)
    
-     ![](https://analyt-mtc.com/illustrations/skc-gas-and-vapour-sampling-accessories.webp)
    
    ### [Gas and Vapour Sampling Accessories](https://analyt-mtc.com/catalog/product/skc-gas-and-vapour-sampling-accessories/)
    
    Sampling-train hardware: low-flow adaptors and CPCs, tube holders and covers, tube breakers and field tools.
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/skc-gas-and-vapour-sampling-accessories/)
    

## [Particulate Sampling](https://analyt-mtc.com/catalog/particulate-sampling/)

42 models

-     ![](https://analyt-mtc.com/illustrations/disposable-parallel-particle-impactors.webp)
    
    ### [Disposable Parallel Particle Impactors](https://analyt-mtc.com/catalog/product/disposable-parallel-particle-impactors/)
    
    Single-use four-impactor sampler for respirable or thoracic PM at 2, 4 or 8 L/min; gravimetric or chemical.
    
    37 mm filter · 2/4/8 L/min
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/disposable-parallel-particle-impactors/)
    
-     ![](https://analyt-mtc.com/illustrations/sureseal-cassette-blanks.webp)
    
    ### [SureSeal Cassette Blanks](https://analyt-mtc.com/catalog/product/sureseal-cassette-blanks/)
    
    Empty two- and three-piece filter housings — clear styrene, solvent-resistant or conductive; leak-tested.
    
    25, 37, 47 mm · 2 or 3-piece
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/sureseal-cassette-blanks/)
    
-     ![](https://analyt-mtc.com/illustrations/cassette-shrink-bands.webp)
    
    ### [Cassette Shrink Bands](https://analyt-mtc.com/catalog/product/cassette-shrink-bands/)
    
    Self-sealing, tamper-evident bands with a writable surface for sample ID; six colours, 25 and 37 mm.
    
    25 & 37 mm · 6 colours
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/cassette-shrink-bands/)
    
-     ![](https://analyt-mtc.com/illustrations/cassette-and-filter-holders.webp)
    
    ### [Cassette and Filter Holders](https://analyt-mtc.com/catalog/product/cassette-and-filter-holders/)
    
    Reusable in-line and open-face holders from 13 to 47 mm in polypropylene, Delrin, polycarbonate or PFA.
    
    13, 25, 37, 47 mm
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/cassette-and-filter-holders/)
    
-     ![](https://analyt-mtc.com/illustrations/filter-supports.webp)
    
    ### [Filter Supports](https://analyt-mtc.com/catalog/product/filter-supports/)
    
    Backing pads and screens under the filter — cellulose, porous plastic or stainless-steel mesh, 25 to 47 mm.
    
    25, 37 and 47 mm
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/filter-supports/)
    
-     ![](https://analyt-mtc.com/illustrations/cassette-inserts.webp)
    
    ### [Cassette Inserts](https://analyt-mtc.com/catalog/product/cassette-inserts/)
    
    Solu-CAP and Accu-CAP dome capsules that capture the whole sample and end cassette wall losses; 37 mm.
    
    37 mm · 0.8 µm MCE
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/cassette-inserts/)
    
-     ![](https://analyt-mtc.com/illustrations/cassette-and-filter-storage.webp)
    
    ### [Cassette and Filter Storage](https://analyt-mtc.com/catalog/product/cassette-and-filter-storage/)
    
    Cases, petri slides, glass jars and Filter-Keeper clamshells for storing and transporting filters to 47 mm.
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/cassette-and-filter-storage/)
    
-     ![](https://analyt-mtc.com/illustrations/filter-sampling-accessories.webp)
    
    ### [Filter Sampling Accessories](https://analyt-mtc.com/catalog/product/filter-sampling-accessories/)
    
    Handling tools — forceps, SureSeal openers, filter lifters, collar clips, tubing, adaptors and sample labels.
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/filter-sampling-accessories/)
    
-     ![](https://analyt-mtc.com/illustrations/mixed-cellulose-ester-membrane-filters.webp)
    
    ### [Mixed Cellulose Ester Membrane Filters](https://analyt-mtc.com/catalog/product/mixed-cellulose-ester-membrane-filters/)
    
    Hydrophilic standard for airborne metals and asbestos fibre counting; dissolves fully for AAS/ICP.
    
    0.45–5.0 µm · 13–47 mm · MCE
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/mixed-cellulose-ester-membrane-filters/)
    
-     ![](https://analyt-mtc.com/illustrations/ptfe-polytetrafluoroethylene-filters.webp)
    
    ### [PTFE (Polytetrafluoroethylene) Filters](https://analyt-mtc.com/catalog/product/ptfe-polytetrafluoroethylene-filters/)
    
    Hydrophobic and solvent-resistant, low tare mass — for size-selective samplers and humid aerosols to 260 °C.
    
    0.3–10 µm · 13–47 mm · PTFE
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/ptfe-polytetrafluoroethylene-filters/)
    
-     ![](https://analyt-mtc.com/illustrations/gla-5000-pvc-membrane-filters.webp)
    
    ### [GLA 5000 PVC Membrane Filters](https://analyt-mtc.com/catalog/product/gla-5000-pvc-membrane-filters/)
    
    Low-tare, hydrophobic media for silica, metals and dust; meets OSHA ID-215 for hexavalent chromium.
    
    5.0 µm · 25–47 mm · PVC
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/gla-5000-pvc-membrane-filters/)
    
-     ![](https://analyt-mtc.com/illustrations/polycarbonate-membrane-filters.webp)
    
    ### [Polycarbonate Membrane Filters](https://analyt-mtc.com/catalog/product/polycarbonate-membrane-filters/)
    
    Smooth-surface film for light and electron microscopy; thin, non-staining, very low tare, to 140 °C.
    
    0.4–0.8 µm · 25–47 mm
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/polycarbonate-membrane-filters/)
    
-     ![](https://analyt-mtc.com/illustrations/silver-membrane-filters.webp)
    
    ### [Silver Membrane Filters](https://analyt-mtc.com/catalog/product/silver-membrane-filters/)
    
    Pure metallic-silver media, inert to 500 °C — for X-ray diffraction of silica and stack sampling.
    
    0.45–0.8 µm · 25–47 mm
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/silver-membrane-filters/)
    
-     ![](https://analyt-mtc.com/illustrations/glass-fibre-depth-filters.webp)
    
    ### [Glass Fibre Depth Filters](https://analyt-mtc.com/catalog/product/glass-fibre-depth-filters/)
    
    Binder-free borosilicate depth media for high-flow gravimetric sampling; 1.0 µm nominal, autoclavable.
    
    1.0 µm nom. · 13–90 mm · glass
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/glass-fibre-depth-filters/)
    
-     ![](https://analyt-mtc.com/illustrations/quartz-depth-filters.webp)
    
    ### [Quartz Depth Filters](https://analyt-mtc.com/catalog/product/quartz-depth-filters/)
    
    Heat-treated quartz for elemental/organic carbon and diesel particulate (NIOSH 5040); withstands 1000 °C.
    
    1.2 µm nom. · 25–102 mm
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/quartz-depth-filters/)
    
-     ![](https://analyt-mtc.com/illustrations/cellulose-depth-filters.webp)
    
    ### [Cellulose Depth Filters](https://analyt-mtc.com/catalog/product/cellulose-depth-filters/)
    
    100% pure ashless cellulose (Whatman Type 40 equivalent) for ashless gravimetric and AA/HPLC methods.
    
    37 mm · ashless · Type 40
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/cellulose-depth-filters/)
    
-     ![](https://analyt-mtc.com/illustrations/gelatin-filters.webp)
    
    ### [Gelatin Filters](https://analyt-mtc.com/catalog/product/gelatin-filters/)
    
    Water-soluble gelatin that keeps microbes viable and dissolves on agar; 3 µm nominal for bioaerosols.
    
    3 µm nom. · 25 & 37 mm
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/gelatin-filters/)
    
-     ![](https://analyt-mtc.com/illustrations/bestchek-asbestos-cassettes.webp)
    
    ### [BestChek Asbestos Cassettes](https://analyt-mtc.com/catalog/product/bestchek-asbestos-cassettes/)
    
    Preloaded MCE cassettes quality-tested for low fibre background; PCM/TEM asbestos with certificate.
    
    0.45–1.2 µm MCE · 25–37 mm
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/bestchek-asbestos-cassettes/)
    
-     ![](https://analyt-mtc.com/illustrations/iso-chek-cassettes.webp)
    
    ### [ISO-CHEK Cassettes](https://analyt-mtc.com/catalog/product/iso-chek-cassettes/)
    
    Dual-filter cassette that traps isocyanate aerosol and vapour at once; MAMA-coated, 1 L/min for 15 min.
    
    5 µm PTFE + GF · 1 L/min
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/iso-chek-cassettes/)
    
-     ![](https://analyt-mtc.com/illustrations/versatrap-spore-trap-cassette.webp)
    
    ### [VersaTrap Spore Trap Cassette](https://analyt-mtc.com/catalog/product/versatrap-spore-trap-cassette/)
    
    Slide-based spore trap; flow sets the 1.5–3.9 µm cut-point for mould counting (ASTM D7391).
    
    1.5–3.9 µm cut · 5–30 L/min
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/versatrap-spore-trap-cassette/)
    
-     ![](https://analyt-mtc.com/illustrations/diesel-particulate-matter-dpm-cyclone.webp)
    
    ### [Diesel Particulate Matter (DPM) Cyclone](https://analyt-mtc.com/catalog/product/diesel-particulate-matter-dpm-cyclone/)
    
    Separates diesel elemental carbon from coal and respirable dust for NIOSH 5040 analysis.
    
    2 L/min · NIOSH 5040
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/diesel-particulate-matter-dpm-cyclone/)
    
-     ![](https://analyt-mtc.com/illustrations/iom-sampler.webp)
    
    ### [IOM Sampler](https://analyt-mtc.com/catalog/product/iom-sampler/)
    
    Reusable weighable cassette traps the inhalable fraction to 100 µm; foam insert adds respirable.
    
    2 L/min · 100 µm · inhalable
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/iom-sampler/)
    
-     ![](https://analyt-mtc.com/illustrations/button-sampler.webp)
    
    ### [Button Sampler](https://analyt-mtc.com/catalog/product/button-sampler/)
    
    Porous curved-surface inlet samples inhalable dust and bioaerosols with low wind sensitivity.
    
    4 L/min · 100 µm · inhalable
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/button-sampler/)
    
-     ![](https://analyt-mtc.com/illustrations/face-level-sampling.webp)
    
    ### [Face Level Sampling](https://analyt-mtc.com/catalog/product/face-level-sampling/)
    
    Dual-arm headset samples welding fume inside masks and helmets to ISO 10882-1.
    
    13 mm MCE · inhalable
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/face-level-sampling/)
    
-     ![](https://analyt-mtc.com/illustrations/plastic-cyclone.webp)
    
    ### [Plastic Cyclone](https://analyt-mtc.com/catalog/product/plastic-cyclone/)
    
    Conductive-plastic respirable cyclone at 3.0 L/min; grit pot and reusable 25 or 37 mm cassette.
    
    3.0 L/min · 4 µm · respirable
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/plastic-cyclone/)
    
-     ![](https://analyt-mtc.com/illustrations/gs-3-respirable-dust-cyclone.webp)
    
    ### [GS-3 Respirable Dust Cyclone](https://analyt-mtc.com/catalog/product/gs-3-respirable-dust-cyclone/)
    
    Multi-inlet respirable cyclone unaffected by wind; 4 µm cut at 2.75 L/min into 25 or 37 mm cassette.
    
    2.75 L/min · 4 µm · respirable
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/gs-3-respirable-dust-cyclone/)
    
-     ![](https://analyt-mtc.com/illustrations/gs-1-respirable-dust-cyclone.webp)
    
    ### [GS-1 Respirable Dust Cyclone](https://analyt-mtc.com/catalog/product/gs-1-respirable-dust-cyclone/)
    
    Single-inlet Dorr-Oliver-equivalent cyclone at 2 L/min; also runs the DPM cassette.
    
    2 L/min · 4 µm · respirable
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/gs-1-respirable-dust-cyclone/)
    
-     ![](https://analyt-mtc.com/illustrations/aluminium-respirable-dust-cyclone.webp)
    
    ### [Aluminium Respirable Dust Cyclone](https://analyt-mtc.com/catalog/product/aluminium-respirable-dust-cyclone/)
    
    Aluminium cyclone with sharp respirable cut for NIOSH 7500 silica; 25 and 37 mm versions.
    
    2.5 L/min · 4 µm · respirable
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/aluminium-respirable-dust-cyclone/)
    
-     ![](https://analyt-mtc.com/illustrations/asbestos-sampling.webp)
    
    ### [Asbestos Sampling](https://analyt-mtc.com/catalog/product/asbestos-sampling/)
    
    Cowled sampling head with 25 mm gridded filter for asbestos fibre counting; plastic or aluminium cowl.
    
    25 mm · 0.8 µm MCE · fibres
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/asbestos-sampling/)
    
-     ![](https://analyt-mtc.com/illustrations/parallel-particle-impactors-ppis.webp)
    
    ### [Parallel Particle Impactors (PPIs)](https://analyt-mtc.com/catalog/product/parallel-particle-impactors-ppis/)
    
    Four impactors in one unit match the respirable or thoracic convention; 2, 4 or 8 L/min models.
    
    2–8 L/min · resp./thoracic
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/parallel-particle-impactors-ppis/)
    
-     ![](https://analyt-mtc.com/illustrations/personal-environmental-monitor-pem.webp)
    
    ### [Personal Environmental Monitor (PEM)](https://analyt-mtc.com/catalog/product/personal-environmental-monitor-pem/)
    
    Impaction sampler for PM2.5 or PM10 indoor air; three flow versions at 2, 4 or 10 L/min.
    
    PM2.5/PM10 · 2, 4, 10 L/min
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/personal-environmental-monitor-pem/)
    
-     ![](https://analyt-mtc.com/illustrations/personal-modular-impactor-pmi.webp)
    
    ### [Personal Modular Impactor (PMI)](https://analyt-mtc.com/catalog/product/personal-modular-impactor-pmi/)
    
    Modular single-stage impactor for PM2.5, PM10 or PM Coarse at 3 L/min; weighs only 71 g.
    
    3 L/min · PM2.5/PM10/Coarse
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/personal-modular-impactor-pmi/)
    
-     ![](https://analyt-mtc.com/illustrations/impact-sampler.webp)
    
    ### [IMPACT Sampler](https://analyt-mtc.com/catalog/product/impact-sampler/)
    
    Ambient PM2.5, PM10 or PM Coarse impactor at 10 L/min onto a 47 mm filter, with rain cover.
    
    10 L/min · PM2.5/PM10 · 47 mm
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/impact-sampler/)
    
-     ![](https://analyt-mtc.com/illustrations/sioutas-personal-cascade-impactor.webp)
    
    ### [Sioutas Personal Cascade Impactor](https://analyt-mtc.com/catalog/product/sioutas-personal-cascade-impactor/)
    
    Cascade impactor collects five size fractions (2.5 to 0.25 µm) at 9 L/min without impaction grease.
    
    9 L/min · 5 stages to 0.25 µm
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/sioutas-personal-cascade-impactor/)
    
-     ![](https://analyt-mtc.com/illustrations/ifv-pro-sampler.webp)
    
    ### [IFV Pro Sampler](https://analyt-mtc.com/catalog/product/ifv-pro-sampler/)
    
    Collects inhalable aerosol and vapour together at 1 L/min for mixed-phase compounds; meets EN 13936.
    
    1 L/min · inhalable + vapour
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/ifv-pro-sampler/)
    
-     ![](https://analyt-mtc.com/illustrations/haz-dust-iv-particulate-monitor.webp)
    
    ### [HAZ-DUST IV Particulate Monitor](https://analyt-mtc.com/catalog/product/haz-dust-iv-particulate-monitor/)
    
    Personal real-time monitor with interchangeable heads and an in-line 37 mm cassette for gravimetric back-up.
    
    0.01–200 mg/m³ · 0.1–100 µm
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/haz-dust-iv-particulate-monitor/)
    
-     ![](https://analyt-mtc.com/illustrations/haz-dust-7204-particulate-monitor.webp)
    
    ### [HAZ-DUST 7204 Particulate Monitor](https://analyt-mtc.com/catalog/product/haz-dust-7204-particulate-monitor/)
    
    Combines a gravimetric sampling pump and optical sensor with a colour touch screen; runs over 22 hours.
    
    0.001–500 mg/m³ · 22 h
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/haz-dust-7204-particulate-monitor/)
    
-     ![](https://analyt-mtc.com/illustrations/split2-particulate-monitor.webp)
    
    ### [Split2 Particulate Monitor](https://analyt-mtc.com/catalog/product/split2-particulate-monitor/)
    
    Passive dust monitor that becomes an active gravimetric sampler when paired with a 2 L/min pump.
    
    0.01–200 mg/m³ · 2 L/min
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/split2-particulate-monitor/)
    
-     ![](https://analyt-mtc.com/illustrations/haz-dust-i-particulate-monitor.webp)
    
    ### [HAZ-DUST I Particulate Monitor](https://analyt-mtc.com/catalog/product/haz-dust-i-particulate-monitor/)
    
    Simple handheld survey tool giving instantaneous respirable dust readings on two selectable ranges.
    
    0.01–200 mg/m³ · 0.1–50 µm
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/haz-dust-i-particulate-monitor/)
    
-     ![](https://analyt-mtc.com/illustrations/epam-5000-particulate-monitor.webp)
    
    ### [EPAM 5000 Particulate Monitor](https://analyt-mtc.com/catalog/product/epam-5000-particulate-monitor/)
    
    Weatherproof ambient monitor with interchangeable PM10, PM2.5, PM1.0 and TSP heads; runs up to 24 hours.
    
    0.001–20 mg/m³ · 4 L/min
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/epam-5000-particulate-monitor/)
    
-     ![](https://analyt-mtc.com/illustrations/air-aide-particulate-monitor.webp)
    
    ### [AIR-AIDE Particulate Monitor](https://analyt-mtc.com/catalog/product/air-aide-particulate-monitor/)
    
    Fixed-point monitor with interchangeable PM1, PM2.5, respirable and PM10 impactors at 2 L/min.
    
    0.001–20 mg/m³ · 2 L/min
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/air-aide-particulate-monitor/)
    
-     ![](https://analyt-mtc.com/illustrations/haz-scanner-epas-air-monitoring-station.webp)
    
    ### [HAZ-SCANNER EPAS Monitoring Station](https://analyt-mtc.com/catalog/product/haz-scanner-epas-air-monitoring-station/)
    
    Multi-sensor perimeter station measuring PM10 and PM2.5 plus up to 14 air parameters simultaneously.
    
    Up to 14 sensors · 1–3 L/min
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/haz-scanner-epas-air-monitoring-station/)
    

## [Surface & Skin Sampling](https://analyt-mtc.com/catalog/surface-skin-sampling/)

17 models

-     ![](https://analyt-mtc.com/illustrations/microvacuum-cassettes.webp)
    
    ### [Microvacuum Cassettes](https://analyt-mtc.com/catalog/product/microvacuum-cassettes/)
    
    Nozzle cassettes vacuuming settled asbestos or fungal spores from carpet and irregular surfaces at 10 L/min.
    
    0.45 µm MCE · ASTM D5755
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/microvacuum-cassettes/)
    
-     ![](https://analyt-mtc.com/illustrations/stick-to-it-lift-tape.webp)
    
    ### [Stick-to-it Lift Tape](https://analyt-mtc.com/catalog/product/stick-to-it-lift-tape/)
    
    Flexible adhesive slide that lifts mould and dust from surfaces; unbreakable and serialised for the lab.
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/stick-to-it-lift-tape/)
    
-     ![](https://analyt-mtc.com/illustrations/ghost-wipes.webp)
    
    ### [Ghost Wipes](https://analyt-mtc.com/catalog/product/ghost-wipes/)
    
    Robust water-moistened wipes for lead and surface metals that fully dissolve in acid digestion for recovery.
    
    ASTM E1792 · NIOSH 9102
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/ghost-wipes/)
    
-     ![](https://analyt-mtc.com/illustrations/wipe-sample-test-kit.webp)
    
    ### [Wipe Sample Test Kit](https://analyt-mtc.com/catalog/product/wipe-sample-test-kit/)
    
    All-in-one OSHA wipe-method kit for metals, pesticides, amines and corrosives — solvents not included.
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/wipe-sample-test-kit/)
    
-     ![](https://analyt-mtc.com/illustrations/sterile-surface-swab-kit-2.webp)
    
    ### [Sterile Surface Swab Kit](https://analyt-mtc.com/catalog/product/sterile-surface-swab-kit-2/)
    
    Sterile rayon swabs in transport tubes for microbial contamination on grills and other irregular surfaces.
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/sterile-surface-swab-kit-2/)
    
-     ![](https://analyt-mtc.com/illustrations/colorimetric-swypes.webp)
    
    ### [Colorimetric SWYPEs](https://analyt-mtc.com/catalog/product/colorimetric-swypes/)
    
    Colour-change indicators for amines, isocyanates, phenols and nickel on surfaces or skin — instant read.
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/colorimetric-swypes/)
    
-     ![](https://analyt-mtc.com/illustrations/permea-tec-pads.webp)
    
    ### [PERMEA-TEC Pads](https://analyt-mtc.com/catalog/product/permea-tec-pads/)
    
    Pads worn inside gloves that colour-change at breakthrough; sensitive to 3–5 µg for amines and isocyanates.
    
    3–5 µg · amines/isocyanates
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/permea-tec-pads/)
    
-     ![](https://analyt-mtc.com/illustrations/full-disclosure-kit.webp)
    
    ### [Full Disclosure Kit](https://analyt-mtc.com/catalog/product/full-disclosure-kit/)
    
    Rhodizonate spot test for lead on skin and surfaces; instant pink bloom, meets NIOSH 9105.
    
    18 µg lead · NIOSH 9105
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/full-disclosure-kit/)
    
-     ![](https://analyt-mtc.com/media/550-200.png)
    
    ### [LeadSense Swab Kit](https://analyt-mtc.com/catalog/product/leadsense-swab-kit/)
    
    Potassium rhodizonate swabs for lead on surfaces; pink or red at 1 µg or more, 10 tests per kit.
    
    ≥ 1 µg lead · 10 swabs
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/leadsense-swab-kit/)
    
-     ![](https://analyt-mtc.com/illustrations/smear-tabs.webp)
    
    ### [Smear Tabs](https://analyt-mtc.com/catalog/product/smear-tabs/)
    
    Low-ash, acid-hardened paper tabs for wipe sampling of settled metals; OSHA ID-121/125G/206.
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/smear-tabs/)
    
-     ![](https://analyt-mtc.com/illustrations/templates.webp)
    
    ### [Templates](https://analyt-mtc.com/catalog/product/templates/)
    
    Manila paper area templates in 10 × 10 cm and 30.5 × 30.5 cm; larger size meets HUD lead guidelines.
    
    10×10 cm · 30.5×30.5 cm
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/templates/)
    
-     ![](https://analyt-mtc.com/illustrations/surface-dermal-test-kits.webp)
    
    ### [Surface/Dermal Test Kits](https://analyt-mtc.com/catalog/product/surface-dermal-test-kits/)
    
    Bundled SWYPEs, PERMEA-TEC pads and decontamination solutions for one target compound group; OSHA validated.
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/surface-dermal-test-kits/)
    
-     ![](https://analyt-mtc.com/illustrations/spill-decontamination-kits.webp)
    
    ### [Spill Decontamination Kits](https://analyt-mtc.com/catalog/product/spill-decontamination-kits/)
    
    Biodegradable clean-up kits for aromatic amine and isocyanate spills; 15 L of solution plus confirming SWYPEs.
    
    15 L solution · SWYPE 3–5 µg
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/spill-decontamination-kits/)
    
-     ![](https://analyt-mtc.com/illustrations/decontamination-solutions.webp)
    
    ### [DECONtamination Solutions](https://analyt-mtc.com/catalog/product/decontamination-solutions/)
    
    Biodegradable solutions that decontaminate surfaces of aromatic amines and isocyanates; 3.75 L or 650 ml.
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/decontamination-solutions/)
    
-     ![](https://analyt-mtc.com/illustrations/d-tam-skin-cleanser.webp)
    
    ### [D-TAM Skin Cleanser](https://analyt-mtc.com/catalog/product/d-tam-skin-cleanser/)
    
    Skin cleanser that lifts water-insoluble amines, pesticides and resins without abrading the skin barrier.
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/d-tam-skin-cleanser/)
    
-     ![](https://analyt-mtc.com/illustrations/methalert.webp)
    
    ### [MethAlert](https://analyt-mtc.com/catalog/product/methalert/)
    
    Colorimetric wet-wipe-spray test for methamphetamine hot spots; qualitative, no training needed.
    
    15–5000 µg/100 cm² · 12 tests
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/methalert/)
    
-     ![](https://analyt-mtc.com/illustrations/methchek.webp)
    
    ### [MethChek](https://analyt-mtc.com/catalog/product/methchek/)
    
    Immunoassay wipe kit for semi-quantitative methamphetamine down to 50 ng; four sensitivity levels.
    
    from 50 ng (0.05 µg/100 cm²)
    
    SKC
    
    [Details →](https://analyt-mtc.com/catalog/product/methchek/)
    

## How do I choose air sampling consumables?

Start from what you need to capture, because the medium follows the contaminant. [Gas and vapour sampling](https://analyt-mtc.com/catalog/gas-and-vapour-sampling/) covers sorbent tubes, diffusive passive samplers, liquid impingers and whole-air sample bags. [Particulate sampling](https://analyt-mtc.com/catalog/particulate-sampling/) covers membrane and depth filters, cassette hardware and size-selective cyclones for dust and fibres.

## Which sampling media suit bioaerosols and surface contamination?

[Bioaerosol samplers](https://analyt-mtc.com/catalog/bioaerosol-samplers/) collect viable, culturable micro-organisms, either into liquid or onto agar plates. [Surface and skin sampling](https://analyt-mtc.com/catalog/surface-skin-sampling/) is the section for contamination that has settled rather than stayed airborne: metals wipes, microvacuum cassettes and colorimetric spot tests.

## Do I need a pump as well?

Sorbent tube sampling, filter cassettes and impingers are pumped: the pump draws sample air through the medium, so its flow rate must match what the method specifies. Passive samplers and wipes need no pump. Compare the flow ranges of the [air sampling pumps](https://analyt-mtc.com/catalog/air-sampling-pumps/) before you order media for a pumped method.

## Questions about these products?

Our application engineers aim to reply within 3 business hours.

[Ask an engineer](https://analyt-mtc.com/contact/?ask=1)